Zanussi ZGF 647 installation manual Building, Input

Page 10

BURNERS

TYPE

TYPE OF

INJECTORS

NOMINAL

REDUCED

NOMINAL

NOMINAL

OF GAS

BURNER

MARKS

POWER

POWER

POWER

PRESSURE

 

 

1/100 mm

INPUT

kW

 

 

mbar

 

 

m3/h

 

 

 

 

KW

 

g/h

 

NATURAL

Rapid (large)

115

2,3

0,575

0,064

-

 

Semi-rapid (medium)

96

1,6

0,400

0,044

-

20

GAS

Auxiliary (small)

64

0,7

0,230

0,019

-

 

GZ 50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPG

Rapid (large)

75

2,1

0,525

-

46

 

(Buthane/

Semi-rapid (medium)

60

1,5

0,375

-

33

36

Propane)

Auxiliary (small)

41

0,7

0,230

-

15

 

 

 

 

 

 

 

 

 

 

 

TOWN

Rapid (large)

180

2,3

0,575

0,089

-

 

GAS

Semi-rapid (medium)

150

1,6

0,400

0,062

-

13

GZ 35

Auxiliary (small)

95

0,7

0,230

0,027

-

 

 

 

 

 

 

 

 

 

9. Building In

SR

A

SR

R

580

A = Auxiliary burner

SR = Semirapid burner

R = Rapid Burner

These hobs can be inserted in a built-in kitchen unit whose depth is between 550 and 600 mm. The hobs dimensions are shown in Fig. 10.

510

Fig. 10

10

Image 10
Contents GAS Hobs Page For Your Safety ManufacturerContents Instruction for the UserHOB LID Cleaning and MaintenanceGeneral Cleaning Automatic IgnitionMainteinance Technical Assistance Periodic MaintenanceOriginal Spare Parts Instruction for the Installer Technical DataHobrecess Dimensions Replacement of the Voltage Cable Electrical ConnectionAdjustment of Minimum Level Replacement of InjectorsAdaptation to different types of gas Building InputAdjusting the LID Balance Fitting the LIDInstallation and Assembly 550Possibilities for Insertion Page Page 01/00