Insulation
The insulated space on this cabinet is sealed to maintain peak efficiency. DO NOT drill holes in the cabinet. Holes drilled in the cabinet may destroy that seal and damage electrical wiring located in the insulated space. It may also pierce and damage the sealed refrigeration system in the insulated space.
DAMAGED ELECTRICAL WIRING OR WET INSULATION CAUSED BY DRILLING WILL VOID THE WARRANTY.
Appliance Start-up
Once the appliance has been located in its permanent location and the proper power and grounding has been provided, the following items must be checked or completed:
Cool Down Period
For safe food storage, allow 24 hours for the appliance to cool down completely before loading with food. The appliance will run continuously for the first several hours. Do not place any food in the appliance until after the first 24 hours of operation.
Thermostat Setting
The appliance is shipped from the factory with the thermostat set at about the
Fig. A | Fig. B |
Position of knob before | Position of knob at end |
turning clockwise to start | of defrost cycle (Second |
defrost cycle (First click) | click) |
Features
NSF and FDA Approved Adjustable Shelving
This appliance is provided with NSF and FDA approved heavy duty epoxy powder coated adjustable shelves. The one with the wires that are angled on the front and back goes on the floor of the cabinet. The others are placed in the adjustable stainless steel shelf supports that clip into the shelf support strips on each side of the interior. Make sure to place the shallow shelf in the
Defrost Setting
The appliance is designed to defrost automatically every 12 hours. To set the time of defrost, wait until the desired time to defrost. With the notch on the timer knob aligned with the line on the bracket (Fig. A), turn the defrost timer knob clockwise slowly. The timer will click several times, then once loudly, at which point the defrost cycle begins. The timer knob will advance through the defrost cycle, then click loudly at the end of the cycle (Fig. B). The appliance will defrost automatically every 12 hours after the first defrost cycle.
Front Fixed and Rear Swivel Casters
This appliance comes with two (2) front fixed casters with brakes and two (2) rear swivel casters. The casters allow the appliance to be moved with ease and then locked in position at its desired location.