.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slot dimensions on page 6). Set range hood aside on a covered surface.
AA
A. Keyhole slot
.Use ¹⁄8” (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot.
A. Drill pilot hole
A
4.Install the 4
¹⁄4”
(6.4 mm)
•For roof installations, remove the top rectangular or round vent knockout depending on which vent system you desire to install. For wall installations, remove the rear rectangular vent knockout.
C
A
A. Top rectangular knockout | B |
B. Rear rectangular knockout |
|
C. Top round knockout |
|
INSTALLING THE HOOD
Vent Connector Installation
Install 7” (17.8 cm) round vent mounting plate or 3¼” x 10” (8.3 x 25.4 cm) vent connector, depending on your vent system installation. Attach to range hood using the indicated screws provided in hardware kit.
| Install the 7” (17.8 cm) |
A | round vent mounting plate |
B | A. .29 x .65 cm screws |
| B. 7” (17.8 cm) round vent |
| mounting plate. |
C | C. Round vent knockout |
| D. Rectangular vent knockout |
| D |
| B |
A | Install the 3¼” x 10” (8.3 x |
25.4 cm) rectangular vent | |
| transition |
| A. 3¼” x 10” (8.3 x 25.4 cm) |
| rectangular vent transition |
| B. .35 x .65 cm screws |
| C. Rectangular vent knockouts |
C
A
B
NOTE
The 7” (17.8 cm) round vent mounting plate or the 3¼” x 10” (8.3 x 25.4 cm) rectangular vent connector can be installed up to 1” (2.5 cm) on either side of the hood center to accommodate off center ductwork.
•If a vent damper is installed with a wall cap with damper, check that they do not interfere with each other. Remove the vent connector damper flap if they interfere.
Power Supply Cable Installation
1.For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box.
11