Frigidaire LI30MB manual List of Materials Electrical Requirements

Page 5

LIST OF MATERIALS

Parts included in your hood

4 - 0.45 x 1.3 cm mounting screws

2 - .35 x .65 cm rectangular vent transition mounting screws

2 - .29 x .65 cm round metal mounting plate mounting screws

3¼” x 10” (8.3 x 25.4 cm) rectangular metal vent system.

7” (17.8 cm) round metal mounting plate.

Parts Needed

2 - UL listed wire connectors

Wall or roof cap with damper to match vent system

Vent clamps/duct tape as required

UL listed or CSA approved ½” strain relief

Tools/Materials required

Drill

1¼” (3.0 cm) drill bit

⅛” (0.3 cm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw

For cabinets with recessed bottoms:

Two - 2” (5.1 cm) wide filler strips. Length and thickness determined by recess dimensions.

Four flat head wood screws or machine screws with washers and nuts (to attach filler strips).

LIST OF MATERIALS

ELECTRICAL REQUIREMENTS

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi- tion) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

.Connect the aluminum wiring to the added section of copper wire using special co nectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer’s recom- mended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate.

The model/serial plate is located on the left side of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (la est edition), or CSA Standards C22. 1-94, Canad an Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.



Image 5
Contents USA Canada LI30MB Feb/13 Product Record and Registration Contents Read all instructions before using this appliance Important Safety InstructionsFire Department List of Materials Electrical Requirements List of MaterialsFor Mobile Home Installations Product DimensionsCabinet Dimensions Location RequirementsVenting Requirements Cold Weather InstallationsMakeup Air Venting MethodsPrepare the Location Determine Wiring Hole LocationTo wire through wall To wire through topWall Venting Style 1 Recirculating Hood versionInstall Vent System Install Range Hood Ducted versionPower Supply Cable Installation Installing the HoodVent Connector Installation Make Electrical Connection Electrical Shock Hazard Disconnect power before servicingComplete Installation Recirculation Vent Cover Do not reconnect power until the installation is complete