INSTALL RANGE HOOD (Recirculating version)

1.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slots dimensions on page 6). Set range hood aside on a

covered surface.

AA

A. Keyhole slot

.Use ¹⁄8” (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot.

A. Drill pilot hole

A

.Install the 4 - .45 cm x 1.3 cm mounting screws in pilot holes. Leave about ¼” (6.4 mm) space between screw heads and cabinet to slide range hood into place.

¹⁄4”

(6.4 mm)

Power Supply Cable Installation

1.For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box.

NOTE

Do not reconnect power until the installation is complete.

INSTALLING THE HOOD

.Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming location of your home power supply cable) and install a UL listed or CSA approved ½” strain relief.

A

A. Power supply knockout

4.Using 2 or more people, lift the hood into final position. Feed enough electrical wire through the ½” UL listed or CSA approved strain relief to make connections in the terminal box. Tighten the strain relief screws.

.Position the range hood so that the large end of the keyhole slots are over the mounting screws.

Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten the mounting screws, making sure the screws are in the narrow neck of slots.

Recirculation Vent Cover

For installations which are recirculating the air exhaust, the recirculation vent cover must be removed. Remove the recirculating

vent cover by removing the 2 mounting screws with a phillips screwdriver.

NOTE: For installations which are venting out the roof or wall, the recirculating vent cover must remain in place. Do not remove as unit will not perform properly.

Part being removed

To complete the installation, go to “Make Electrical Connection” section on page 12.

.Remove the screw from the terminal box cover. Remove terminal box cover and set aside.

A. Terminal box cover

B. Screw

A

B

13

Image 13
Contents USA Canada LI30MB Feb/13 Product Record and Registration Contents Read all instructions before using this appliance Important Safety InstructionsFire Department List of Materials Electrical Requirements List of MaterialsFor Mobile Home Installations Product DimensionsCabinet Dimensions Location RequirementsVenting Requirements Cold Weather InstallationsMakeup Air Venting MethodsPrepare the Location Determine Wiring Hole LocationTo wire through wall To wire through topWall Venting Style 1 Recirculating Hood versionInstall Vent System Install Range Hood Ducted versionVent Connector Installation Installing the HoodPower Supply Cable Installation Complete Installation Electrical Shock Hazard Disconnect power before servicingMake Electrical Connection Recirculation Vent Cover Do not reconnect power until the installation is complete