47
Table for the Choice of the Injectors |
|
| Cat: II 2H3+ | ||
|
|
|
|
|
|
Burners | Nominal |
| Reduced | G30 - | G20 - 20 mbar |
| Power |
| Power | G31 - 37 mbar |
|
| kW |
| kW |
|
|
| Ø Injector | Ø Injector | |||
|
|
|
| ||
|
|
|
| 1/100 mm | 1/100 mm |
|
|
|
|
|
|
Auxiliary (A) | 1,00 |
| 0,30 | 50 | 72 (X) |
|
|
|
|
|
|
1,75 |
| 0,45 | 65 | 97 (Z) | |
Rapid (R) | 3,00 |
| 0,75 | 85 | 115 (Y) |
Triple Ring (TR) | 3,50 |
| 1,50 | 95 | 135 (T) |
Increase of Air Necessary for Gas Combustion (2 m3/h x kW)
Burners | Air necessary for combustion (m3/h) |
Auxiliary (A) | 2,00 |
3,50 | |
Rapid (R) | 6,00 |
|
|
Triple Ring (TR) | 7,00 |
|
|
Lubrication of the Gas Taps
The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the