48
Electrical Installation
WARNING! Electricity can be extremely dangerous.
This appliance must be earthed.
The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate.
It is recommended that the appliance is connected directly to the mains by fixed wiring, placing a double pole switch with minimum opening between the contacts of 3 mm.
The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point.
Once the cooker has been installed, the switch must always be accessible.
Before effecting any intervention on the electrical parts the appliance must be disconnected from the network.
Electrical Feeder Cable Connection
To connect the feeder cable to the cooker it is necessary to:
–Remove the screw that hold shield “A” behind the cooker (fig. 48).
–Insert the feeder cable of the suitable section (as described in the next chapter) into the cable clamp “D”.
–Connect the phase and earth cables to the terminal block “B” according to the diagram in figure 47.
–Pull the feeder cable and block it with cable clamp “D”.
–
230 V
L1 N PE
Fig. 47 | (L2) |
|
Feeder Cable Section
Type H05RRF
230 V~ 3 x 2.5 mm2 (**)
(**) - Connection with wall box connection.
Earth cable must be 2 cm longer than neutral and live cables.
PE | D |
B |
|
| A |
Fig. 48 |
|