Electrolux Gas hob manual Important safety requirements

Page 13

Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room with a volume of less than 20 m³. If it is installed in a room of volume less than 5 m³ an air vent of effective area of 110 cm² is required. If it is installed in a room of volume between 5 m³ and 10 m³ an air vent of effective area of 50 cm² is required, while if the volume exceeds 11 m³ no air vent is required.

However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m³ and 11 m³.

If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.

This hob must be installed by qualified personnel to the relevant British Standards.

Any gas installation must be carried out by a CORGI registered installer.

The maufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored

13

Image 13
Contents INSTRUCTION- and Installation Book Your New Appliance Table of contents Safety information Air intake Description of the productBurner markings OperationsPanel markings Ignition electrode a Burner cover/inner burner ring/outer burner ringThermo couple B Ignition Maintenance and cleaning Ceramic glass Stainless steel surfacesDo not use any kind of scouring powder ThegasburnerTechnical data Important safety requirements Pressure test Headroom MountingFixing Cut-out measurementsInstallation in work tops with a base unit underneath Do not install the hob above drawers Mm Cooker hood 290 mm Unit´s externally measured length580 mm Something not working SymptonSolution08705 929 Service & spare partsHelp us to help you Customer CareGuarantee conditions Germany FranceItaly SwedenPage 325 88-1620 Rev