Electrolux Gas hob manual Technical data

Page 12

Technical data

Type of gas

Adjusted to natural gas: G20-20 mbar

Category and pressures

UK: II2H3+ 20 mbar - 28/37 mbar

Max. nominal load Q na HS:

Medium sized burner =

1,9 kW x 1

Large sized burner =

2,7 kW x 1

Total=

4,6 kW

FSD

The unit features fully-secured gas taps (thermo-fuse).

HS = Top calorific value

Q = Nominal load

ID. CE-048AU-0002

Ignition transformer= 50 HZ - 0,6 VA

Radio-noise reduction

This unit observes the current EEC- directive on radio noise reduction.

This gas appliance is -approved and marked in accordance with the gas appliance Directive (90/396/CEE), the low voltage directive (73/23/CEE) and the EMC directive (89/336/CEE incl. the agreed directive changes.

240 V

1N + PE

N L1

The hob must be connected via an external switch with a contact gap of min. 3 mm (the main switch may be used)

Wiring

HO5V2V2-F

Blue and brown: 51 mm +/- 3 mm

Yellow/Green: 61 mm +/- 3 mm

Cable type 0,75 mm² HO5 V2V2-F

12

Image 12
Contents INSTRUCTION- and Installation Book Your New Appliance Table of contents Safety information Description of the product Air intakeOperations Burner markingsPanel markings Burner cover/inner burner ring/outer burner ring Ignition electrode aThermo couple B Ignition Maintenance and cleaning Stainless steel surfaces Ceramic glassThegasburner Do not use any kind of scouring powderTechnical data Important safety requirements Pressure test Mounting HeadroomFixing Cut-out measurementsInstallation in work tops with a base unit underneath Do not install the hob above drawers Unit´s externally measured length Mm Cooker hood 290 mm580 mm SymptonSolution Something not workingService & spare parts 08705 929Help us to help you Customer CareGuarantee conditions France GermanyItaly SwedenPage 325 88-1620 Rev