Electrolux EKG5542 manual Connecting to GAS Supply, Fitting the Stability Chain, Pressure Testing

Page 29

CONNECTING TO GAS SUPPLY

This appliance is designed to be installed with an appliance flexible connection only. Supply piping should not be less than R3/8. Connection is made to the Rc ½ (½” B.S.P.) female threaded entry pipe located just below the hotplate level on the rear left hand side of the appliance. NOTE: ONLY LIQUID

SEALANTS TO BE USED WHEN INLET GAS PIPE IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT TAPE. Carry out a gas tightness test after connecting to the gas supply. The gas bayonet connector must be fitted in the shaded area indicated in Fig.3. Take into account that it must be possible to pull the appliance forward sufficiently. Ensure the hose does not become trapped when pushing the appliance into position.

IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY WITH BS.669 CURRENT EDITION.

LPG Flexible connections must be a type suitable for L.P.G and capable of operation up to 50 mbar and carry a red stripe, band or label.

FITTING THE STABILITY CHAIN

It is recommended that if the appliance is to be installed with a flexible supply pipe, a stability chain be fitted and is available from your supplier (see Important Safety Requirements). These instructions should be read in conjunction with any leaflet packed with the stability chain.

1.Place the appliance in its intended position and level appliance.

2.Mark a position 100mm from the top of the rear right hand corner.

3.Measure down 150mm from this point. This gives the position of the wall anchor point for the stability chain.

4.The stability chain anchor point on the appliance is shown in the diagram Fig. 4.

PRESSURE TESTING

1.The Rapid injector is used as a pressure test point.

2.Connect the pressure gauge to the Rapid injector.

3.Check the supply pressure by turning the Rapid burner on and one other hotplate burner full on and light the appropriate burner. The pressure should be either:-

(i)For Natural Gas 20mbar

(ii)For LP. Gas. The pressure must be set to 29 mbar for use on butane or 37 mbar for use on propane.

4.Turn off the taps, disconnect the pressure gauge.

5.Check operation of each hotplate burner.

Fig.3.

Fig.4.

29

Image 29
Contents Model EKG5542/EKG5543 Installation Important Safety InformationChild Safety Cleaning and MaintenanceContents SLIP-IN GAS Oven Description of the ApplianceControl Panel FeaturesGetting to Know Your Appliance Before Using the Appliance HOB Using the HOBTo Light the HOB Burners To Turn OFF ANY BurnerHints and Tips Things to NoteGrill Using the GrillGrill PAN and Handle Ensure the handle is correctly locatedPosition FoodGrill Time Mins in totalMain Oven Using the Main OvenHeat Zones PreheatingHints and Tips Cook Time min Cooking ChartFood Position GAS Approx Mark Cooking Time Roasting ChartFood Preparation Slow Cooking Using Slow CookSlow Cook Vegetables Cleaning Materials Care and CleaningCleaning the Outside of the Appliance Cleaning the Control Knobs and HandlesCleaning the Grill Cleaning the HOBWhen Replacing Hotplate Burner Parts Aerosol cleaners must not be used on Stayclean surfaces Cleaning Inside the Grill and Oven CompartmentsCleaning Between the Outer and Inner Door Glass Cleaning the DoorsTo Replace the Outer Glass To Remove the Outer GlassReplacing AN Oven Light Bulb Something not WORKING? ProblemPossible Solution Service and Spare Parts This guarantee does not cover Guarantee ConditionsTechnical Details Provision for Ventilation Installation InstructionsImportant Safety Requirements Moving Your Appliance For Your SafetyLocation of Appliance Levelling the ApplianceIf a moulded plug is fitted Connecting to the Electricity SupplyConnect to 230-240 A.C supply only Fitting the Stability Chain Connecting to GAS SupplyPressure Testing Checking the Hotplate Checking the GrillChecking LID SHUT-OFF Device Checking the Main OvenPage Important Notice