TECHNICAL DETAILS
DIMENSIONS |
|
Height: | 900 mm (nominal) |
Width: | 550 mm (nominal) |
Depth: | 600 mm (to front of door panel) |
Weight: | 58 Kg Net |
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level See important note 'Location of Appliance'.
Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)
CONNECTIONS |
|
|
|
|
Gas connection: - | Rear left hand side of appliance at hotplate level |
| ||
| Rc ½ (½” B.S.P. female) |
|
| |
Electrical connection: - | 230 - 240 V 50 Hz Mains connected at rear centre of appliance using at | |||
| least 2.5mm2 multi core PVC insulated cable. |
| ||
HOTPLATE | Natural Gas |
|
|
|
|
|
|
| |
Heat Input | R.H.F | R.H.F | L.H.R | L.H.F |
| 1.0kW | 1.9kW | 1.9kW | 3.0kW |
| (3412 Btu/h) | (6483 Btu/h) | (6483 Btu/h) | (10236 Btu/h) |
Injector Marking | 070 | 096 | 096 | 119 |
| L.P.Gas |
|
|
|
Heat Input | 1.0kW | 2.0kW | 2.0kW | 2.8kW |
| (71.8g/h) | (143.6g/h) | (143.6g/h) | (194.0g/h) |
Injector Marking | 050 | 071 | 071 | 086 |
GRILL | Natural Gas |
| L.P.Gas |
|
Heat Input | 2.7kW (9212 Btu/h) | 2.7kW (194g/h) |
| |
Injector Marking | 120 |
| 95 |
|
MAIN OVEN |
|
|
|
|
Heat Input | 1.9kW (6483 Btu/h) | 1.9kW (136.5g/h) | ||
Injector Marking | 099 |
| 070 |
|
Thermostat | 75 |
| 80 |
|
Thermostat | 75 |
| 80 |
|
GENERAL |
|
|
|
|
Ignition | (H.T. Spark) |
|
|
|
Spark Gap |
|
|
| |
GAS CATEGORY COUNTRIES OF DESTINATION |
|
|
| |
CAT. I2H | GB |
|
|
|
CAT. I3+ | GB |
|
|
|
This appliance complies with: European Council Directives Low voltage Directive 73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking Directive 93/68/EEC.
25