INSTALLATION INSTRUCTIONS FOR FREESTANDING GAS RANGE
Fig. 4d
Fig. 4e
“ ON ”
Fig. 4f
DO NOT allow regulator to turn on pipe when tightening fittings.
a)Install an external manual gas
b)Install 1/2" flare union adapter to pressure regulator using NO MORE THAN 15ft./lbs. of torque
NOTE: Be sure to stabilize the left side of the pressure regulator with adjustable wrench before tightening ANY fittings to the pressure regulator (Refer to Fig. 4d).
c)Tighten the gas supply fitting and/or appliance conduit to flare union on the right side of the pressure regulator using NO MORE THAN 15ft./lbs. of torque.Be sure to stabilize
the 1/2" flare union adapter with an adjustable wrench before tightening the gas supply fitting and/or appliance conduit (Refer to Fig. 4e).
d)Install flare union adapter to external manual
e)Attach appliance conduit to flare union on
f)Make sure service
g)Check for leaks. Turn the gas supply on to the appliance and use a liquid leak detector at all joints and conduits to check for leaks in the system.
Do not use flame to check for gas leaks. Checking Manifold Gas Pressure
Disconnect the range and its individual
The appliance must be isolated from the gas supply piping system by closing its individual manual
If it should be necessary to check the manifold gas pressure, connect manometer (water gauge) or other pressure device to the top burner right rear orifice. Using a rubber hose with inside diameter of approximately 1/4," hold tubing down tight over orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other top burners burning. Be sure the gas supply (inlet) pressure is at least one inch above specified range manifold pressure. The gas supply pressure should never be over 14" water column. When properly adjusted for Natural Gas the manifold pressure is 4."
5.Read these electrical connection details first then connect electricity to appliance.
Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord.
Electric Requirements: A dedicated, properly grounded and polarized branch circuit protected by a 15 amp. circuit breaker or time delay fuse. See serial plate for proper voltage.
Extension Cord Precautions:
Because of potential safety hazards under certain conditions, we strongly recommend against the use of any extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed