INSTALL THE DUCTWORK

(This section for F30WV hoods only. F24WR and F30WR hoods skip this section and go on to “Install Range Hood”.)

NOTE These instructions will follow plans made on Page 2. Start at the exterior and run ductwork back to the range hood.

For best possible performance, use the shortest possible duct run and a minimum number of elbows. Do not vent a range hood into an attic space. A buildup of grease in the attic could become a fire hazard.

Use only metal ductwork. DO NOT USE PLASTIC DUCT. As- semble duct run securely so that in case of a grease fire on the range, the fire will be contained inside metal ductwork.

Tape all duct connections.

1.Follow appropriate directions below for type of duct run you install.

a.) Wall Cap Discharge; (FIG. 7) Use saber saw or keyhole saw to cut hole slightly larger than duct size used so that duct will line up easily with damper/duct conector on hood. Install casing strips if cap will be installed on siding. Attach required amount of duct to wall cap and run duct back to hood. Fasten cap to wall and caulk well.

b.) Roof Cap Discharge; (FIG. 8) Cut a hole in roof slightly larger than duct size being used. Run ductwork down to hood location. Leave 3/4" of duct projecting above roof surface on high side.

Trim duct parallel to roof pitch and seal all around duct with roof cement.

Carefully trim shingles and slide back of roof sheet under shingles. Nail roof sheet to roof under shingles at top two corners and two sides. Nail sheet directly to roof in four places at bottom.

Using roof cement, seal all nail heads and shingles which were cut or lifted. Do not seal bottom edge of roof sheet.

INSTALL RANGE HOOD

WARNING

TURN OFF THE PROPER CIRCUIT AT THE SERVICE ENTRANCE BEFORE WIRING THIS RANGE HOOD.

1.Run electric wiring through hole drilled in wall or cabinet. Split wir- ing for 6" and install proper connector for type of wire used. (FIG. 9)

2.Position hood so that:

a.) Wiring is routed through knockout opening (FIG. 10) b.) Large part of keyhole slots fit over hood mounting screws.

(FIG. 10)

c.) Damper/duct connector slides into ductwork. (F30WV hoods only)

3.Adjust hood so that hood front is flush with cabinet frame.

4.Tighten hood mounting screws firmly.

5.Fasten wiring to hood with proper electrical connector for type of wire being used.

WARNING

ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALL- ING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALI- FIED ELECTRICIAN.

6.Strip 1/2" of insulation from wires. Connect white to white, black to black, and green to prepared hole with green ground screw pro- vided. (FIG. 11)

7.Replace wiring box cover and screw. Make sure that all wiring is safely contained inside.

8.Install light (75 Watt maximum). For easier installation, squeeze plas- tic lens and remove it from hood. Remember to reinstall lens. (FIG.12)

9.Turn on power and check operation of fan and light. Make sure that damper operates freely.

FIG. 5A

FILLER

STRIP

CENTER LINE

HOOD WIDTH

**10-15/16" FOR 24" RANGE HOOD, 13-15/16" FOR 30" RANGE HOOD

FIG. 5B

F24WR,F30WR & F30WV

FIG. 6

KEYHOLE SLOT OUTLINE

FILLER STRIPS

CENTER

LINE

FIG. 7

SOFFIT

WALL CAP

CABINET

FIG. 8

ROOF CAP

DUCT

SOFFIT

CABINET

4

Image 4
Contents To Reduce the Risk of a Range TOP Grease Fire Intended for Domestic Cooking onlyEvacuate and Call the Fire Department Planning Ductwork Installation Tools and Materials RequiredPrepare the Installation Location Prepare the HoodInstall Range Hood Install the DuctworkTape all duct connections USE and Care Ducted Hood Service PartsDescription F30WR & F24WR Series NON-DUCTED Hood Major Appliance Warranty Information Exclusions This warranty does not cover the following