DeLonghi DEGH60BG, DEGH70BG, DEGH90BG manual Installation with a Flexible Hose Assembly

Page 12

5.Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position, the flame must not go out. If adjustment is required carry out the “minimum burner setting adjustment” procedure described below.

6.If satisfactory performance cannot be obtained, the installer shall check the installation and notify the local gas supply authority for a gas supply problem, or if it is an ap- pliance problem, our Customer Service Centre should be called to obtain the nearest authorized Delonghi Service Agent.

7.Where the appliance data plate cannot be easily read with the appliance in the instal- led position the duplicate data plate must be attached to adjacent surface and the du- plicate Natural gas / ULPG conversion label should also be included where a Natural gas / ULPG conversion has been completed.

INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY

■■ If this appliance has to be installed with a hose assembly, the installer shall refer to the network operator or gas supplier for confirmation of the gas type, if in doubt.

■■ When used with a flexible hose, the connector on the wall should be between 800 mm to 850 mm above the floor and in the region outside the width of the appliance to a distance of 250 mm.

The supply connection point shall be accessible with the appliance installed.

■■ Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certified.

The thread connection shall be Rp 1/2” (ISO 7-1) male.

■■ IMPORTANT WARNING: After connection the installer must check that the hose is not kinked, subjected to abrasion or permanently deformed. The installer must check also that the hose is not near (or in contact) with any hot surfaces e.g. base of metal hotplate, underbench oven etc.

■■ The hose assembly shall be as short as practicable and comply with relevant AS/NZS5601 requirements.

■■ IMPORTANT WARNING: The installer shall ensure the hose assembly is restrained from accidental contact with the flue outlet of an underbench oven.

Figure 9

12

Image 12
Contents BUILT-IN GAS on Glass Hobs Page Dear Customer Product LabelImportant Precautions and Recommendations Installation Electrical RequirementsDEGH90BG 840 ClearancesModel DEGH60BG Installing the SEPARA- TOR below the Base of the Cooktop Standards requirementFastening the Cooktop Natural GAS GAS SupplyInstallation with a Flexible Hose Assembly Table for the Choice of the Injectors UlpgReplacing the Injectors Minimum Burner Setting Adjustment Lubricating the GAS TAPUSE and Care GAS Burners Control KnobsUsing GAS Burners Lighting GAS Burners Fitted with Flame Failure Safety Device Cooking Hints for GAS HobsWrong CorrectPage General Advice Glass SurfaceEnamelled Parts GAS TapsBurners and Grids Important WarningGH90BG Page Service and Maintenance Lubrication of the GAS TapsPage Cod ß1