DeLonghi DEGH60BG Standards requirement, Installing the SEPARA- TOR below the Base of the Cooktop

Page 9

The installation shall comply with the dimensions in Figures 3a, 3b or 3c and 4a, 4b or 4c, bearing in mind that:

■■ A partition between the base of the hob and the cupboard below should be fitted 30

mmbelow the workbench surface if the cupboard is to be used for storage.

■■ If the hob is installed over a built-in oven, the oven shall be provided with cooling fan motor. The two appliances shall be connected to the gas/electrical supply with inde- pendent connections.

■■ Overhead clearances - In no case shall the clearance between the highest part of the hob and a range hood be less than 600 mm, or for an overhead exhaust fan 800 mm. Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with local regulations inforce. However, in no case shall this clea- rance to any surface be less than 450 mm.

Standards requirement

Temperature of nearby surfaces. Australian and New Zealand Gas Installation Stan- dards (AS/NZS5601) require a cooktop to be installed so that the surface temperature of any nearby combustible surface will not exceed 65°C above ambient.

This is typically achieved by:

■■ having the cooktop spaced away from the wall (see figures 3a, 3b or 3c and 4a, 4b or 4c);

AND

■■ protecting the wall to a height of at least 150 mm along its length (minimum height of non-combustible material when used on adjacent walls) with non-combustible surface materials such as:

––5 mm-thick ceramic tiles (these alone are adequate);

––tempered glass or sheetmetal, minimum thickness 0.4 mm (acceptable when used in front of a fire resistant material).

INSTALLING THE SEPARA- TOR BELOW THE BASE OF THE COOKTOP

It is recommended that a 30 mm clearance be left between to base of the cooktop and the separator.

The separator shall be heat resi- stant, made of low thermal con- ductivity material and shall be re- movable with the use of a tool for installation and service.

 

Figure 5

Clearance

30 mm

Separator

 

Space for

 

connections

 

 

9

Image 9
Contents BUILT-IN GAS on Glass Hobs Page Product Label Dear CustomerImportant Precautions and Recommendations Electrical Requirements InstallationDEGH90BG Clearances 840Model DEGH60BG Standards requirement Installing the SEPARA- TOR below the Base of the CooktopFastening the Cooktop GAS Supply Natural GASInstallation with a Flexible Hose Assembly Ulpg Table for the Choice of the InjectorsReplacing the Injectors Lubricating the GAS TAP Minimum Burner Setting AdjustmentUSE and Care Control Knobs GAS BurnersUsing GAS Burners Cooking Hints for GAS Hobs Lighting GAS Burners Fitted with Flame Failure Safety DeviceCorrect WrongPage Glass Surface General AdviceEnamelled Parts GAS TapsImportant Warning Burners and GridsGH90BG Page Lubrication of the GAS Taps Service and MaintenancePage Cod ß1