DeLonghi DEGH70BG, DEGH60BG, DEGH90BG manual Table for the Choice of the Injectors, Ulpg

Page 13

TABLE FOR THE CHOICE OF THE INJECTORS

 

Natural Gas

ULPG

Test Point Pressure

 

1.0

 

2.75

[kPa]

 

 

 

 

 

 

 

 

 

Injector

 

Gas

Injector

 

Gas

BURNER

Orifice Dia.

 

Consumption

Orifice Dia.

 

Consumption

 

[mm]

 

[MJ/h]

[mm]

 

[MJ/h]

 

 

 

 

 

 

 

Auxiliary (AUX)

0.85

 

3.60

0.53

 

3.60

Semi-rapid (SR)

1.12

 

6.30

0.70

 

6.30

Rapid (R)

1.45

 

10.40

0.91

 

10.80

Triple-ring (TR) (*)

1.60

 

12.70

0.95

 

11.90

(*) Only for the models DEGH70BG, DEGH90BG

(Note: Gas type sticker and data plate are attached to the underside of the base of the appliance.)

13

Image 13
Contents BUILT-IN GAS on Glass Hobs Page Product Label Dear CustomerImportant Precautions and Recommendations Electrical Requirements InstallationDEGH90BG Clearances 840Model DEGH60BG Standards requirement Installing the SEPARA- TOR below the Base of the CooktopFastening the Cooktop GAS Supply Natural GASInstallation with a Flexible Hose Assembly Ulpg Table for the Choice of the InjectorsReplacing the Injectors Lubricating the GAS TAP Minimum Burner Setting AdjustmentUSE and Care Control Knobs GAS BurnersUsing GAS Burners Cooking Hints for GAS Hobs Lighting GAS Burners Fitted with Flame Failure Safety DeviceCorrect WrongPage Glass Surface General AdviceEnamelled Parts GAS TapsImportant Warning Burners and GridsGH90BG Page Lubrication of the GAS Taps Service and MaintenancePage Cod ß1