Maytag W10252706B wire connection Power Supply Cord, A B C D, E. Neutral center wire

Page 9
A

3.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A 3-wire connection: Power Supply CordE. Neutral (center) wireD. Neutral (white) wireManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

C

Manual backgroundD

A. Terminal block

B.Ground-link screw

C.UL listed strain relief

D.Power supply cord wires

4.Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw and ground-link section. The ground wire must be attached first.

5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.

1.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

C

Manual backgroundD

A. Terminal block

B.Ground-link screw

C.UL listed strain relief

D.Power supply cord wires - large opening

2.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

A

F

 

B

 

C

E

 

 

D

A. 10–32 hex nut

D. Green ground wire

B. Ground-link screw

E. Neutral (center) wire

C. Line 2 (red)

F. Line 1 (black)

6.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

7.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8.Tighten strain relief screws.

9.Replace terminal block access cover.

A

E

 

B

D

 

C

 

A. 10–32 hex nut

D. Neutral (white) wire

B. Line 2 (red)

E. Line 1 (black)

C.Ground-link screw

3.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

4.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

5.Tighten strain relief screws.

6.Replace terminal block access cover.

9

Image 9
Contents W10252706B INSTALLATION INSTRUCTIONS 30 76 CM FREESTANDING ELECTRIC RANGESTable of Contents RANGE SAFETY Your safety and the safety of others are very importantDANGER Mobile Home - Additional Installation Requirements INSTALLATION REQUIREMENTSTools and Parts Location RequirementsCabinet Dimensions Product DimensionsElectrical Requirements - U.S.A. Only A C B D EIf connecting to a 4-wire system If connecting to a 3-wire systemElectrical Connection Install Anti-Tip Bracket INSTALLATION INSTRUCTIONSUnpack Range A D C BPower Supply Cord Direct WireElectrical Connection - U.S.A. Only Style 1 Power supply cord strain relief 4-wire connection Power Supply CordStyle 2 Direct wire strain relief connecting toA B C D 3-wire connection Power Supply CordE. Neutral center wire D. Neutral white wire4-wire Connection Direct Wire Direct Wire Installation Copper or Aluminum WireBare Wire Torque Specifications A B CDEA B CD E 3-wire connection Direct WireD. Bare green ground wire E. Neutral white wireLevel Range Verify Anti-Tip Bracket LocationStorage Drawer To RemoveTo Replace Complete InstallationFor power supply cord-connected ranges For direct-wired rangesMoving the Range Top edge Left edge ANTI-TIP BRACKET TEMPLATE2009 W10252706B9/09 All rights reserved