AGA ELECTRIC RANGE (EC LM - 2 OVEN & EE LM - 4 OVEN) - OWNERS MANUAL

This appliance must be connected to a grounded, metallic, permanent supply or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.

Failure to follow these instructions could result in death or serious injury.

A four-wire single phase 240-volt, 60-Hz, AC-only electrical supply is required on a separate, 30-amperes circuit, fused on both sides of the line. (See Fig. 2A - for wiring details).

A time-delay fuse or circuit breaker is required.

Local codes permit the use of a U.L. listed, 250-volt, 30-amperes power cord. This cord contains four No.10 copper wires and matches a four-wire receptacle of type 14-50P.

Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the range (30-amperes).

The wiring diagram is located on the back of the L.H. door.

THIS APPLIANCE MUST HAVE THE FACILITY OF BEING COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY.

THE APPLIANCE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY BEFORE SERVICING.

WARNING

Electrical Grounding Instructions

This appliance is equipped with a grounding pin for your protection against a shock hazard and should be plugged directly

INSTRUCTIONS

Hand this Owners Manual to the user for retention and instruct in the safe operation of the appliance.

Also advise the user that, for continued efficient and safe operation of the appliance that servicing is carried out at intervals recommended by the Aga distributor.

ELECTRICAL TEST PROCEDURE

Final Electrical Test - Electric Voltage - Withstand Test

Procedure:

(Earth Appliance Test Simulation)

1.Select 1200 volts Flash Test on test equipment.

2.Plug in supply plug into the test equipment.

3.Depress the ‘Test Button' for 1 second.

4.A 'Pass' light will illuminate.

5.If the appliance fails this test, re-check all circuits and correct the fault and retest the range.

6.Disconnect from the test equipment and connect range to its permanent supply.

7.A full load test will be performed using a clamp meter connected to the incoming supply. NOTE: The test results 10.5 -11 amps normal operation.

file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS513307/EINS513307.htm (8 of 18)8/16/2006 9:18:22 AM

Image 8
Contents AGA Electric Range For USE in USA/CANADA Contents Section InstallationInstallation General NotesTiling Installation RequirementsRange Base or Hearth Desn Desn Electrical Connection Electrical Grounding Instructions Electrical Test ProcedureInstructions Make note of results and disconnect all leads Safety Precautions Ventilating Hoods Where ApplicableBasic Range Safety Precautions User ServicingGrease Child SafetyRange Cooking Safety Precautions and Hints Range Accessories Heat IndicatorGeneral Safety Precautions and Hints for cooking utensils Thermostat ControlAfter your Aga has been assembled ServicingOperating Your AGA Beginning to cook on your Aga Fitting of Oven ShelvesRemoval of Oven Shelves Cleaning and Caring for Your AGA Top Plate and Front plateDo not USE ANY Oven Cleaners Insulating Covers and Oven DoorsOven and Hotplates Roasting TinsLOW Simmering Oven