ELECTRICAL CONNECTION

The appliance shall be connected to a single phase electric line rated at 120/208Vac or 120/240Vac and 60Hz frequency.

Electric power rating:

120/208Vac: 2400 Watt or 12.0 A max.

120/240Vac: 3100 Watt or 13.5 A max.

Heating elements power rating:

Oven bake element = 1800 Watt

Oven circular element = 3000 Watt

Oven double broil element = 1200+1800 Watt

Install a suitable electric power supply receptacle connection type NEMA 14‐50R able to support a load of at least 16 A (per line) according to local code requirements. For four or three wires power supply connection system see diagram below.

FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R

THREE-WIRE CONN.RECEPTACLE NEMA 14-50R

Check your local code for which of the options below should be used in grounding the receptacle power supply connections.

OPTION 1 – FOUR Wires connection:

Connect the L1 receptacle terminal to the incoming BLACK electrical supply wire (L1‐hot wire)

Connect the L2 receptacle terminal to the incoming RED electrical supply wire (L2‐hot wire)

Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL (WHITE) electrical supply wire

Connect the GROUND receptacle terminal to the incoming GROUND (GREEN) electrical supply wire

OPTION 2 - THREE-Wires connection:

Connect the L1 receptacle terminal to the incoming BLACK electrical supply wire (L1‐hot wire)

Connect the L2 receptacle terminal to the incoming RED electrical supply wire (L2‐hot wire)

Connect the NEUTRAL with the GROUND receptacle terminal to the incoming NEUTRAL (WHITE) electrical supply wire

DO NOT USE EXTENSION CORDS WITH THIS APPLIANCE AS IT MAY RESULT IN FIRE, ELECTRIC SHOCK OR OTHER type of

PERSONAL INJURY.

The appliance is equipped at the factory with an electric supply cord set 4 wires type with ring terminals (L1, L2, N, Ground) suitable for range use UL/CSA listed type SRDT/DRT 2x6AWG (L1, L2)+2x8AWG (N, G) rated 300V, 40 or 50A with fused plug type NEMA 14‐50P; cable length 1,5 m.; in case the supply cord set must be replaced, it shall be replaced with an identical set having the same technical specs and following carefully the instructions and diagrams below:

1)Disconnect appliance from electrical power supply receptacle

2)Slide out the appliance from installation place to access to back enclosure panel

3)Remove back enclosure panel by removing the 6 screws as shown below

13

Image 13
Contents Models MAS365DFMXE From the desk of the President Table of Contents Important Appliance Information Customer Service Warranty and ServiceReplacement Parts What to do if YOU Smell GAS Important Safety InformationLP gas Product SpecificationsType of GAS Before InstallationInstalling the Worktop Frontguard Installing the LegsInstalling the Backguard Electrical Installation RequirementsGAS Exhaust Hood Installation Installation Adjacent to Kitchen CabinetsElectrical Connection Electrical Grounding Electrical Shock Hazard Wiring Diagram GAS Connection Do not USE AN Open Flame When Checking For LeaksManual SHUT‐OFF Valve Flexible ConnectionsPressure Regulator GAS ConversionSurface Burners Minimum Flame AdjustmentGAS Burners Data Tables Final Preparation Installation ChecklistRoom Ventilation Surface Burner Layout SymbolsSurface Cooking Electric Ignition Surface Burner Operation Thermocouple Safety ValveManual Ignition Oven Cooking Tips for Using Pans CorrectlyOven Function Selector Oven RacksLight Bake Using the OvenConvection Rack Positions ConvectionBaking Recommendations Broil / Convection BroilBeef Broiling and Roasting RecommendationsCleaning Your Range Care and MaintenanceMaintaining Your Range Oven Problem Possible Causes AND/OR Remedy Troubleshooting GuideImportant Appliance Information Italy