Bertazzoni MAS365DFMXE manual Before Installation, Type of GAS

Page 8

BEFORE INSTALLATION

This appliance shall only be installed by an authorized professional.

This appliance shall be installed in accordance with the manufacturer’s installation instructions.

This appliance must be installed in accordance with the norms & standards of the country where it will be installed. The installation of this appliance must conform to local codes and ordinances. In the absence of local codes, Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1 – latest edition** or B149.1.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified design, max. 5 feet (1,5 m) long, ½” I.D. is recommended for connecting this appliance to the gas supply line. Do not bend or damage the flexible connector when moving the appliance.

This appliance must be used with the pressure regulator provided. The regulator shall be properly installed in order to be accessible when the appliance is installed in its final location. The pressure regulator must be set for the type of gas to be used. The pressure regulator has ½” female pipe thread. The appropriate fitting must be determined based on the size of your gas supply line, the flexible metal connector and the shutoff valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

All opening and holes in the wall and floor, back and under the appliance shall be sealed before installation of the appliance.

A manual valve shall be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance

WARNING: This appliance shall not be installed with a ventilation system that air downward toward the range/rangetop/cooktop; this type of ventilation system may cause ignition and

8

combustion problem with the gas cooking appliance resulting in a personal injury or unintended operation.

WARNING: an air curtain or other overhead range/rangetop/cooktop hood, which operates by blowing a downward airflow onto a

range/rangetop/cooktop, shall not be used/installed in conjunction with this gas range/rangetop/cooktop.

WARNING!

Do not use aerosol sprays in the vicinity of this

appliance while it is in operation

ROOM VENTILATION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the appropriate national and local standards. Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the appropriate national and local standards.

TYPE OF GAS

This appliance is shipped from the factory for use with natural gas. For use with propane LP gas please follow the conversion procedure described on pg. 17. A step by step conversion procedure is also included with each set of LP gas nozzles.

GAS PRESSURE

The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’ water column (5 kPa) .

The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c. (1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa for LP Gas).

Image 8
Contents Models MAS365DFMXE From the desk of the President Table of Contents Important Appliance Information Replacement Parts Warranty and ServiceCustomer Service Important Safety Information What to do if YOU Smell GASProduct Specifications LP gasBefore Installation Type of GASInstalling the Legs Installing the Worktop FrontguardInstalling the Backguard GAS Installation RequirementsElectrical Installation Adjacent to Kitchen Cabinets Exhaust Hood InstallationElectrical Connection Electrical Grounding Electrical Shock Hazard Wiring Diagram Do not USE AN Open Flame When Checking For Leaks GAS ConnectionManual SHUT‐OFF Valve Flexible ConnectionsGAS Conversion Pressure RegulatorMinimum Flame Adjustment Surface BurnersGAS Burners Data Tables Installation Checklist Final PreparationRoom Ventilation Surface Cooking SymbolsSurface Burner Layout Manual Ignition Surface Burner Operation Thermocouple Safety ValveElectric Ignition Tips for Using Pans Correctly Oven CookingLight Oven RacksOven Function Selector Convection Using the OvenBake Convection Rack PositionsBroil / Convection Broil Baking RecommendationsBroiling and Roasting Recommendations BeefMaintaining Your Range Care and MaintenanceCleaning Your Range Troubleshooting Guide Oven Problem Possible Causes AND/OR RemedyImportant Appliance Information Italy