Verona VEBIG24 warranty Gas connection, Manual Shut-off Valve fig, Pressure Regulator

Page 19

gas connection

￿

 

 

 

Explosion Hazard

Use a new CSA or UL approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connec- tions.

If connected to LP, have a quali- fied person make sure gas pres- sure does not exceed 14" water column.

Examples of a qualified person include licensed heating per- sonnel, authorized gas compa- ny personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to the action of LP/Propane gas.

The oven is equipped for the use with NATURAL gas. It is design-certified by CSA International for NATURAL and L.P. gases with appropriate conversion.

The model/serial rating plate, located on the back of the oven, has information on the type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier. See page 23 for L.P. gas conversion inctructions.

1. Manual Shut-off Valve (fig. 6.1):

A manual shut-off valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance (In Massachusetts such shutoff devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters). This valve should be located in the same room as the oven and should be in a location that allows ease of opening and closing (in a position where it can be reached quickly in the event of an emergency).

Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.

Shutoff valve

“open” position

To oven

Gas supply line

Fig. 6.1

2. Pressure Regulator:

a)All heavy duty, commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation, since service pressure may fluctuate with local demand.

Before installing the regulator mount the 3/8” NPT (conical) male connector to the regulator (see picture 6.2a). Gasket supplied have to be placed between 3/8” NPT (conical) connector/manifold male pipe fitting (see picture 6.2b).

The regulator supplied with this oven must be installed before any gas connections are made.

Use supplied pressure regulator only.

19

Image 19
Contents I L T I N G a S O V E N What to do if YOU Smell GAS Dear Customer User Instructions Important Precautions and RECOM- MendationsRemove the door before disposal to prevent entrapment Control Panel Fig Control panelMinute Counter fig 60’ alarm knobOven Burner How to use the gas ovenGeneral Features Using the Oven for the First TimeOven Cooking Ignition of the Oven BurnerOven Light Ignition of the Broil BurnerBroiling Cleaning and maintenance Replacing the Oven Light Oven DoorRemoving the Oven Door DO’S and do NOT’S For Your SafetyInstallation Instructions Electrical Grounding Instructions Replacement PartsInstallation to the Cabinet Installation= = Manual Shut-off Valve fig Gas connectionPressure Regulator Pressure Regulator Installation Step GAS Connection Specification Rigid Pipe Connections Flexible ConnectionsSetting the Pressure Regulator Leak TestingInjectors Table Oven burner Adjustment of the Oven Burner Minimum Recommended ground method Electrical connectionElectric Diagram Cod ß1

VEBIG24 specifications

Verona VEBIG24 is a cutting-edge solution designed for modern heating needs, renowned for its efficiency and advanced technology. This innovative heating appliance caters to both residential and commercial applications, delivering reliable performance tailored to various environments.

One of the standout features of Verona VEBIG24 is its powerful condensing technology. This enables the boiler to recover heat from exhaust gases, significantly increasing overall energy efficiency. By maximizing the use of available energy, the VEBIG24 reduces fuel consumption and lowers greenhouse gas emissions, making it an environmentally friendly choice.

The VEBIG24 operates on multiple fuel types, including natural gas and propane, providing versatility for users. Its compatibility with different energy sources allows for easy integration into existing heating systems, making it a practical option for various applications. The unit boasts a robust output capacity, ensuring that it meets the heating demands of even the largest spaces.

Additionally, Verona has incorporated smart controls into the VEBIG24, allowing users to easily monitor and adjust settings through a user-friendly interface. These intelligent controls enhance the efficiency of the heating system by enabling precise temperature regulation and scheduling. Users can optimize their energy usage, which not only saves money but also promotes sustainable living.

Safety and reliability are paramount in the design of the VEBIG24. It comes equipped with advanced safety features, including flame failure protection and pressure monitoring systems, ensuring trouble-free operation. The boiler is constructed using high-quality materials that guarantee durability and long-term performance, reflecting Verona's commitment to excellence.

Moreover, the Verona VEBIG24 is characterized by its compact design, making it suitable for installations in limited spaces. Its modern aesthetic allows it to blend seamlessly into a variety of environments without compromising on performance.

In summary, the Verona VEBIG24 is an exemplary heating solution that combines advanced technology, efficiency, and reliability. Its condensing capabilities, versatile fuel options, smart controls, robust safety features, and compact design make it an ideal choice for anyone looking to enhance their heating system while prioritizing sustainability and cost-effectiveness. Whether for home or commercial use, the VEBIG24 stands out as a premium heating option in today's market.