b)Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work is started on the oven. (Gas conversions are the responsibility of the dealer or end user.)

c)This oven can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with NATURAL gas.

d)Manifold pressure should be checked with a manometer; NATURAL gas requires 4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P. (see figure below).

Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than the manifold pressure in order to check the regulator.

The regulator used on this oven can withstand a maximum input pressure of 1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a step-down regulator will be required.

To oven

 

Screw

Manifold

 

 

test point

 

pressure

 

1/8” NPT

Unscrew

 

To mains

Fig. 6.4

connection

e)The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 PSI (3.5 kPa).

f)The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).

3. Flexible Connections:

If local codes permit, CSA design-certified, flexible metal appliance connector is recommended for connecting this oven to the gas supply line. Do Not kink or damage the flexible connector when moving the oven. The pressure regulator has 3/8" NPT female pipe threads.You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve.

4. Rigid Pipe Connections:

If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the oven. All strains must be removed from the supply and fuel lines so oven will be level and in line.

Use joint compounds and gaskets that are resistant to action of natural or propane gas on all male pipe threads.

Do not over tighten gas fitting when attaching to pressure regulator. Over tightening may crack regulator.

22

Image 22
Contents I L T I N G a S O V E N What to do if YOU Smell GAS Dear Customer Important Precautions and RECOM- Mendations User InstructionsRemove the door before disposal to prevent entrapment Control panel Control Panel Fig60’ alarm knob Minute Counter figUsing the Oven for the First Time How to use the gas ovenGeneral Features Oven BurnerIgnition of the Oven Burner Oven CookingIgnition of the Broil Burner Oven LightBroiling Cleaning and maintenance Replacing the Oven Light Oven DoorRemoving the Oven Door For Your Safety DO’S and do NOT’SInstallation Instructions Replacement Parts Electrical Grounding InstructionsInstallation Installation to the Cabinet= = Manual Shut-off Valve fig Gas connectionPressure Regulator Pressure Regulator Installation Step GAS Connection Specification Flexible Connections Rigid Pipe ConnectionsSetting the Pressure Regulator Leak TestingInjectors Table Oven burner Adjustment of the Oven Burner Minimum Electrical connection Recommended ground methodElectric Diagram Cod ß1

VEBIG24 specifications

Verona VEBIG24 is a cutting-edge solution designed for modern heating needs, renowned for its efficiency and advanced technology. This innovative heating appliance caters to both residential and commercial applications, delivering reliable performance tailored to various environments.

One of the standout features of Verona VEBIG24 is its powerful condensing technology. This enables the boiler to recover heat from exhaust gases, significantly increasing overall energy efficiency. By maximizing the use of available energy, the VEBIG24 reduces fuel consumption and lowers greenhouse gas emissions, making it an environmentally friendly choice.

The VEBIG24 operates on multiple fuel types, including natural gas and propane, providing versatility for users. Its compatibility with different energy sources allows for easy integration into existing heating systems, making it a practical option for various applications. The unit boasts a robust output capacity, ensuring that it meets the heating demands of even the largest spaces.

Additionally, Verona has incorporated smart controls into the VEBIG24, allowing users to easily monitor and adjust settings through a user-friendly interface. These intelligent controls enhance the efficiency of the heating system by enabling precise temperature regulation and scheduling. Users can optimize their energy usage, which not only saves money but also promotes sustainable living.

Safety and reliability are paramount in the design of the VEBIG24. It comes equipped with advanced safety features, including flame failure protection and pressure monitoring systems, ensuring trouble-free operation. The boiler is constructed using high-quality materials that guarantee durability and long-term performance, reflecting Verona's commitment to excellence.

Moreover, the Verona VEBIG24 is characterized by its compact design, making it suitable for installations in limited spaces. Its modern aesthetic allows it to blend seamlessly into a variety of environments without compromising on performance.

In summary, the Verona VEBIG24 is an exemplary heating solution that combines advanced technology, efficiency, and reliability. Its condensing capabilities, versatile fuel options, smart controls, robust safety features, and compact design make it an ideal choice for anyone looking to enhance their heating system while prioritizing sustainability and cost-effectiveness. Whether for home or commercial use, the VEBIG24 stands out as a premium heating option in today's market.