Verona CTG212FD warranty Using the gas cooktop, Lighting GAS Burners, Choice of Burner fig

Page 5

using the gas cooktop

GAS BURNERS

Gas flow to the burners is adjusted by turning the knobs (illustrated in fig. 2.1) which control the valves.

Turning the knob so that the indicator line points to the symbols printed on the panel achieves the following functions:

OFF = closed valve

HI = maximum rate

LO = minimum rate

The maximum aperture position permits rapid boiling of liquids, whereas the minimum aperture position allows simmer warming of food or maintaining boiling conditions of liquids.

To reduce the gas flow to minimum, rotate the knob further anti-clockwise to point the indicator towards the LO position.

Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positions, and never between the maximum aperture and OFF positions.

N.B. When the cooktop is not being used, set the gas knobs to their OFF posi- tions and also close the gas shut-off valve placed on the main gas supply line.

LIGHTING GAS BURNERS

In order to light the burner, you must:

1 – Turn the knob in an anti-clockwise direction up to the LITE-HI position (maximum rate), push in and hold the knob until the flame has been lit (fig. 2.2).

The sparks produced by the lighter situated inside the relative burner will light the flame.

In the event that the local gas supply conditions makes it difficult to light the burn- er in HI position, try again with the knob in LO position.

If there is no mains electrical supply, bring a lighted match close to the burner.

2 – Adjust the gas valve to the desired position.

To re-light the burner, return the knob to the OFF position and repeat the operations for lighting.

DIAMETERS OF PANS WHICH MAY BE USED ON THE COOKTOP

BURNER

MINIMUM

MAX.

Semirapid

4" 11/16 (12 cm)

9" 7/16 (24 cm)

Rapid

9" 7/16 (24 cm)

10" 1/4 (26 cm)

 

Do not use pans with concave or convex bases

 

CHOICE OF BURNER (fig. 2.3)

The symbols printed on the panel beside the gas knobs indicate the correspondence between the knob and the burner.

The most suitable burner is to be chosen according to the diameter and volume capac- ity of the container to be warmed.

It is important that the diameter of the pots or pans suitably match the heating poten- tial of the burners in order not to jeopardise the efficiency of the burners, bringing about a waste of gas fuel.

A small diameter pot or pan placed on a large burner does not necessarily mean that boiling conditions are reached quicker.

Caution!

The cooktop becomes very hot during operation.

Keep children well out of reach.

Fig. 2.1

Fig. 2.2

Fig. 2.3

5

Image 5 Contents
Model CTG212FD Dear Customer Tips for the User Important Precautions and RecommendationsControl Panel Description FeaturesGAS Burners Using the gas cooktopLighting GAS Burners Choice of Burner figCleaning and maintenance Burners and Grids Correct Replacement of the BurnersTools Needed for Installation Installation InstructionsElectrical Grounding Instructions Replacement PartsCooktop Dimensions Installation to the cabinetFastening the Cooktop .3 Proximity to Side CabinetsManual Shut-off Valve fig Gas connectionExplosion Hazard Step Pressure Regulator Installation StepGasket GAS Connection SpecificationScrew Manifold Test point Pressure NPT Unscrew Flexible ConnectionsSetting the Pressure Regulator fig Leak TestingRigid Pipe Connections Conversion to LP/PROPANE GASInjectors Table Operations to be Performed When Substituting the InjectorsRegulating the Burner Minimum Setting Recommended ground method Electrical connectionWiring diagram key Wiring DiagramCod ß2