200CHAG~INSIANDAPDPIUQUMIING
210Programming Operations
All programming procedures remain standard as in Section 300 of the Electra-616 Installation Service Manual NE-17314. This includes all procedures for going off-line, for selecting memory blocks and addresses, for entering data, etc.
210.1Programming Details
Several parameters have been added to the programrrable contents of the system memory, these are:
--Privacy release which disables privacy on selected lines enabling up to four stations to talk to an outside partyon any CD/pBX line assign& to be without privacy.
--Assignment of ET-G&( ) Key Telephone Sets with internal speakerphone to allow full hands-free operation including initiation of intercom calls.
--Selection of a vacant station position to enable tarxlem conference (a tandem conference being an unsupervised conferexe of two outside (a/PBX) parties with manual re-entry to monitor conference status),
--A method of resetting the system by programming (without using the momentary button on the CPU) has been added.