Sharp R-216LS service manual Before Servicing, When the testing is completed, After repairing

Page 4

R216LS

CHAPTER 1. WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock.

(Example)

High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions.

Don't Touch !

Danger High Voltage

[1] Before Servicing

1.Disconnect the power supply cord , and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

WARNING: RISK OF ELECTRIC SHOCK. DISCHARGE THE HIGH-

VOLTAGE CAPACITOR BEFORE SERVICING.

The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short- circuit the connection of the high-voltage capacitor (that is the connect- ing lead of the high-voltage rectifier) against the chassis with the use of an insulated screwdriver.

Whenever troubleshooting is performed the power supply must be disconnected. It may, in some cases, be necessary to connect the power supply after the outer case has been removed, in this event,

1)Disconnect the power supply cord, and then remove outer case.

2)Open the door and block it open.

3)Discharge high voltage capacitor.

4)Disconnect the leads to the primary of the power transformer.

5)Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.

6)After that procedure, reconnect the power supply cord.

[2] When the testing is completed,

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Reconnect the leads to the primary of the power transformer.

5.Reinstall the outer case (cabinet).

6.Reconnect the power supply cord after the outer case is installed.

7.Run the oven and check all functions.

[3] After repairing

1.Reconnect all leads removed from components during testing.

2.Reinstall the outer case (cabinet).

3.Reconnect the power supply cord after the outer case is installed.

4.Run the oven and check all functions.

Microwave ovens should not be run empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two (2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold carry out Before Servicing procedure and re-exam- ine the connections to the component being tested.

When all service work is completed and the oven is fully assembled, the microwave power output should be checked and microwave leak- age test should be carried out.

1 – 1

Image 4
Contents Model R-216LS Precautions for Using Lead Free Solder Component ReplacementAdjustment Procedure Microwave Measurement PROBefore Servicing After repairing When the testing is completedBefore Servicing Microwave Measurement Procedure Preparation for testingRequirements Leakage testForeword and Warning ForewordProduct Description 1 Specifications DescriptionOven Diagram General InformationGrounding Instructions OvenTouch Control Panel Power Level Cooking Power Output ReductionDescription of Operating Sequence OFF ConditionSchematic Door Closed Clock Appears on Display Oven SchenaticOff Condition Cooking ConditionDescription and Function of Components Troubleshooting Guide Troubleshooting ChartTest Procedures Procedure a Magnetron Assembly TestProcedure B Power Transformer Test Procedure C High Voltage Rectifier TestProcedure D High Voltage Capacitor Test Procedure E Temperature Fuse Oven TestProcedure F Secondary Interlock Switch Test Procedure F Primary Interlock System TestProcedure H Blown Minitor Fuse Test Procedure G Monitor Switch TestPrimary Interlock Relay RY2 Procedure I Noise Filter Test Procedure J Touch Control Panel Assembly TestKey Unit Control UnitProcedure K KEY Unit Test Procedure L Relay TestProcedure M Defrost Test Procedure N Foil Pattern on the Printed Wiring Board TestR216LS Touch Control Panel Assembly Precautions for Handling Electronic ComponentsOutline of Touch Control Panel Servicing for Touch Control PanelOther Precautions Servicing ToolsPrecautions for Using LEAD-FREE Solder Using lead-free wire solderEmploying lead-free solder SolderingComponent Replacement and Adjustment PROCE- Dure Outer Case RemovalPower Transformer Removal Positive Lock Connector NO-CASE Type RemovalReinstall Magnetron RemovalGraphic Sheet and Membrane Switch Replacement Control Panel Assembly RemovalTrol Panel Assembly Removal Turntable Motor Removal Power Supply Cord ReplacementCooling FAN Motor Removal Installation AdjustmentMake Sure That the FAN Blade Rotates Smooth After Installed Make Sure That the Axis of the Shaft is not SlantedAfter adjustment, check the following Door ReplacementAfter any service, make sure of the following Figure C-7. Door Replacement Sealer FilmDiagrams Pictorial Diagram FigureControl Panel Circuit Figure S-2 Liquid Crystal DisplayPrinted Wiring Board Figure S-3 DIPUnit CodeMeno Parts Guide Oven Parts Oven Parts Parts Code Price NEW Description Rank MarkDoor and Control Panel Parts Door and Control Panel Parts „INDEX

R-216LS specifications

The Sharp R-216LS is a versatile microwave oven that combines affordability with a range of features designed to enhance your cooking experience. Compact yet powerful, this model is especially suitable for small kitchens or dorm rooms, where space is at a premium.

One of the standout features of the Sharp R-216LS is its impressive 800 watts of cooking power. This ensures quick and efficient heating, allowing users to prepare meals in a fraction of the time compared to conventional ovens. The microwave also features a variety of power levels, providing flexibility for different types of cooking and reheating tasks, from defrosting frozen food to cooking delicate items like baked goods.

The R-216LS comes equipped with a spacious 20-liter capacity, which is surprisingly roomy for its size. This allows for ample space to heat up large dishes or multiple servings at once. The interior is designed with easy cleaning in mind, featuring a non-stick coating that prevents food from adhering to the surfaces and simplifies maintenance.

In terms of usability, the Sharp R-216LS boasts a user-friendly interface with straightforward knobs and buttons. It includes a timer and a range of pre-programmed cooking options, enabling users to cook a variety of foods with just the touch of a button. This is particularly beneficial for those new to microwave cooking or for busy individuals looking to save time.

The microwave also incorporates advanced technologies, including inverter microwave technology, which provides a continuous stream of cooking power for more even heating and defrosting. This ensures that your food is cooked thoroughly without the risk of hot and cold spots.

Safety is another priority in the design of the R-216LS. It features a child safety lock, which prevents accidental operation, making it a perfect choice for families with young children. The model also has an automatic shut-off feature, ensuring that the microwave turns off when not in use.

In summary, the Sharp R-216LS is a compact microwave that offers a blend of power, convenience, and safety features, making it an excellent choice for anyone seeking a reliable cooking appliance. Whether for reheating leftovers, cooking meals, or defrosting ingredients, this microwave is designed to meet the diverse needs of modern kitchens. With its combination of thoughtful design and functionality, the R-216LS stands out as a worthy investment for those looking for efficiency and performance in their cooking appliances.