Moyer Diebel 501-HTN, 501-LT technical manual Maintenance Schedule, As Required, Weekly

Page 18

MAINTENANCE

Maintenance Schedule

As Required

1.Check the temperature gauge reading.

2.Check the chemical supplies and refill as necessary.

Weekly

1.Inspect all water lines for leaks and tighten them at joints if required.

2.Clean all detergent residue from the exterior of the machine.

3.Check the drain for leaks.

4.Clean accumulated scale from the heating element.

5.Remove and closely inspect each spray arm for blockage.

6.Check for damage to the scrap screen. Ineffective screening can cause wash system failures.

7.Clean the detergent, sanitizer, and rinse aid supply tubes. Complete the following procedure:

a.Remove the detergent, sanitizer, and rinse aid pick-up tube(s) from the container(s). Place the tube(s) into a container of hot water.

b.Depress and hold the DET prime switch (located on the front panel) until clear water enters the tank through the fill air gap (located on the right side of the tank).

c.If your machine is equipped with a sanitizer and/or rinse aid pump, follow the same procedure by pressing the SANITIZER and/or the RINSE AID prime switch until clear water enters the tank through the fill air gap.

d.When completed, remove the pickup tubes from the hot water and reinsert them into the correct chemical containers. Repeat the priming procedures to ensure that chemicals have filled the tubes for the next operating period.

e.Run a complete cycle to flush chemicals from the tank.

12

Image 18
Contents Technical Manual Moyer Diebel Limited Moyer Diebel, US Revision History This Intentionally Left Blank Contents Detergent Pump Assembly Introduction Welcome to Moyer DiebelLimited Warranty Standard equipment includes Model NumbersOptions Accessories Electrical Power RequirementsWire Plus Ground Diagram Unpacking Electrical ConnectionsRinse Aid Plumbing ConnectionsDetergent Chemical SanitizerCompleting Installation Operation Procedures Operation Summary501LT 60C/140F Extended Wash Cycle To use the Extended Wash CycleCleaning Schedule Daily-Every 8 HoursMeal Periods Deliming Deliming ProcessMaintenance Schedule As RequiredWeekly Troubleshooting Condition Cause SolutionTroubleshooting con’t Replacement Parts Track and Panel Assembly TRACK/PANEL Assembly Part Description Qty Item NoDoor Switch Assembly Door & Switch Assembly Tank Heat and Drain Tank HEAT/DRAIN Assembly Part DescriptionPump Assembly Pump Assembly Wash System Assembly Wash System Assembly 715 Water Inlet Piping Assembly Fill System Fill System All Models Part DescriptionBooster Assembly Booster Assembly Includes Models HT, UT, UT-LC Part DescriptionDetergent Pump Assembly Detergent Pump Assembly Detergent To Fill Pump see FIG System To Chemical Supply SANITIZER/RINSE AID Pump LT/UTL Drain Pump Assembly Drain Pump Assembly 501 UTL, UT-LC Part DescriptionControl Cabinet Control Cabinet Assembly HT, HTN, LT, UTL, UT, UT-LC Control Cabinet Assembly cont’d Electrical Schematics Electrical Schematics Electrical Diagram, 501-HT For machines Ranging from S/N Electrical Diagram, 501-HTN For machines beginning with S/N Electrical Diagram, 501-LT For machines beginning with S/N Electrical Diagram, 501-HT 50 Hz To Customer Disconnect Switch 115V Neutral Electrical Diagram, 501-HTN For machines built prior to S/N CLT If Used Timer Assembly 501HT Timer Assembly 501HT Timer Assembly 501UT Timer Assembly 501LT