ELECTRICAL SCHEMATICS
6 |
CAM 1 |
TO CUSTOMER RECEPTACLE
115V 60Hz
BLK WHT
GND
1
2
00012
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz, AS SPECIFIED PER ORDER, TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT MUST COMPLY WITH ALL LOCAL ELECTRICAL CODES.
TTS 10 | WHTR |
| 2 |
8 | 2 |
CLT |
|
NC | 7 | NC |
| 8 | 8 | TM |
|
|
| 2 |
|
|
|
|
|
|
| |
|
|
|
| 13 |
| BLU START CW | |
| 9 | 9 SRC 12 | 3 |
|
| RED START CCW | |
24 | 2 | 9 |
|
| |||
|
|
|
| 2 |
| ||
1 |
|
| 15 |
| 15 | BLK | MAIN |
|
|
|
| ||||
|
|
|
|
|
| 3 |
|
|
| CAM |
| 2 |
| WHT |
|
| 8 |
|
|
| 4 |
| |
|
|
|
|
| GRN |
| |
|
|
|
|
|
|
| |
|
| 20 | DP | 2 |
| 5 |
|
|
|
|
|
|
|
| |
|
| CAM | D V | 2 |
|
|
|
| 8 |
|
|
|
| ||
| NC |
| 2 |
|
|
| |
|
| 16 |
|
|
|
|
|
|
| 21 |
| 2 |
|
|
|
| 8 | CAM | DM |
|
|
|
|
| NC |
|
|
|
|
| |
| 1 |
|
|
|
|
|
|
|
| 17 | (IF USED) |
|
|
|
|
|
| CAM | RM | 2 |
|
|
|
| 8 |
|
|
|
| ||
| NC |
|
|
|
|
|
BLK | BLACK | CLT | CYCLE ON LIGHT |
| PSDR | PRIME SWITCH DETERGENT, RINSE | |
BLU | BLUE | DM | DETERGENT MOTOR | RM | RINSE MOTOR | (IF USED) | |
BTS | BOOSTER THERMOSTAT | DP | DRAIN PUMP | (IF USED) | SRC | CURRENT OPERATED START RELAY COIL | |
CAM 1 | HOMING | DS | DOOR SWITCH |
| TM | TIMER MOTOR |
|
CAM 2 | PUMP MOTOR | DV | DRAIN VALVE |
| TP | THERMAL PROTECTOR | |
CAM 3 | PUMP MOTOR REVERSING | EW/D | EXTENDED WASH/DELIME | TTS | TANK HEATER THERMOSTAT | ||
CAM 4 | DRAIN | FV | FILL VALVE |
| WHT | WHITE |
|
CAM 5 | FILL | GND | GROUND |
| WHTR | WATER HEATER |
|
CAM 6 | RINSE | GRN | GREEN |
|
|
|
|
CAM 7 | DETERGENT | HLTS | HIGH LIMIT THERMOSTAT |
|
|
| |
CAM 8 | MSW | MAIN SWITCH ON/FILL OFF/DRAIN |
|
|
|
Figure 19 - Electrical Diagram, 501-HTN (For machines built prior to S/N 6984)