Moyer Diebel 501-LT, 501-HTN technical manual Timer Assembly 501LT

Page 59

ELECTRICAL SCHEMATICS

00016

TIMING CHART 501LT

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

CAM

TIME IN SECS

 

 

1

HOMING

 

 

 

 

CAM

 

 

 

 

2

WASH PUMP

 

 

FORWARD=WASH

 

 

 

 

 

2

WASH PUMP

 

 

REVERSE=DRAIN

 

 

 

 

 

 

WASH PUMP

 

 

3REVERSING CAM DRAIN VALVE

4DRAIN PUMP

5FILL VALVE RINSE

6PUMP SANITIZER

7PUMP DETERGENT

8PUMP AUTO-FILL

9DRAIN

N N

C O

COM.

TIMER

SWITCH

DETAIL

9

 

 

 

 

 

 

 

SYNCHRON

8

7

6

5

4

3

2

1

LOCKING SCREW

 

 

 

 

TIMER MOTOR

 

 

 

 

 

TIMER ASSEMBLY 501LT

Figure 24 - Timer Chart and Diagram, 501-LT

53

Image 59
Contents Technical Manual Moyer Diebel Limited Moyer Diebel, US Revision History This Intentionally Left Blank Contents Detergent Pump Assembly Welcome to Moyer Diebel IntroductionLimited Warranty Options Standard equipment includesModel Numbers Wire Plus Ground Diagram AccessoriesElectrical Power Requirements Electrical Connections UnpackingChemical Sanitizer Plumbing ConnectionsDetergent Rinse AidCompleting Installation 501LT 60C/140F Operation ProceduresOperation Summary To use the Extended Wash Cycle Extended Wash CycleMeal Periods Cleaning ScheduleDaily-Every 8 Hours Deliming Process DelimingWeekly Maintenance ScheduleAs Required Condition Cause Solution TroubleshootingTroubleshooting con’t Replacement Parts Track and Panel Assembly Part Description Qty Item No TRACK/PANEL AssemblyDoor Switch Assembly Door & Switch Assembly Tank Heat and Drain Part Description Tank HEAT/DRAIN AssemblyPump Assembly Pump Assembly Wash System Assembly Wash System Assembly 715 Water Inlet Piping Assembly Fill System All Models Part Description Fill SystemBooster Assembly Includes Models HT, UT, UT-LC Part Description Booster AssemblyDetergent Pump Assembly Detergent Pump Assembly Detergent To Fill Pump see FIG System To Chemical Supply SANITIZER/RINSE AID Pump LT/UTL Drain Pump Assembly 501 UTL, UT-LC Part Description Drain Pump AssemblyControl Cabinet Control Cabinet Assembly HT, HTN, LT, UTL, UT, UT-LC Control Cabinet Assembly cont’d Electrical Schematics Electrical Schematics Electrical Diagram, 501-HT For machines Ranging from S/N Electrical Diagram, 501-HTN For machines beginning with S/N Electrical Diagram, 501-LT For machines beginning with S/N Electrical Diagram, 501-HT 50 Hz To Customer Disconnect Switch 115V Neutral Electrical Diagram, 501-HTN For machines built prior to S/N CLT If Used Timer Assembly 501HT Timer Assembly 501HT Timer Assembly 501UT Timer Assembly 501LT