Operation

Operation

5.Operation

5.1.Filling the Wash Tank

Ensure that the overflow drain tube is in place in the detergent tank.

Flip power on-off/flush switch to the “ON” position. The water will fill until the proper level is reached then turn the heating element “ON”.

The water temperature is controlled by a heater and a thermostat .The thermostat should be set for minimum 140°F/60°C.

5.2.Operating Instructions

Open the door; flip power on-off/flush switch to the “ON” position. Wash tank will automatically fill.

Ensure there is product in the detergent, sanitizer and rinse agent containers.

Detergent is fed from the supply container into the detergent tank in controlled amounts by the detergent pump. Use detergent at strength recommended by your chemical supplier.

Load glasses on the conveyor. Start machine with GL-C rocker switch located on front right side of unit. Machine now will stop and start with conveyor shut-off rod.

3.2.1.Proper Chemical Dosage

The amount of chemical delivered, whether it is detergent, sanitizer or rinse aid, can be obtained by counting the revolutions of the injector rotors.

For detergent, contact your chemical supplier for proper type and detergent concentration. Note: Detergent pump only operates when hot water tank is filling.

For sanitizer, one revolution in 5 seconds equals approximately 12.5ppm Iodine or 50ppm chlorine.

For rinse agent, one revolution in 8 seconds is recommended.

To Adjust Detergent Injector:

When a new detergent container is installed, push the prime button in and hold until the detergent feed tube is full.

Install the overflow drain tube and switch power on-off/flush switch to the “ON” position. The detergent feeder will now feed detergent into the detergent tank with water fill.

To increase detergent volume, turn the detergent adjustment screw clockwise.

To decrease the detergent volume, turn the detergent adjustment screw counter-clockwise.

To Adjust Sanitizer Injector:

When a new sanitizer container is installed, push the prime button in and hold until sanitizer feed tube is full.

Start the washer with rocker switch located on the front of the machine. Take a sample from the final rinse spray tube to check sanitizer level.

To increase the volume of sanitizer, turn the adjustment screw clockwise.

To decrease the volume of sanitizer, turn the adjustment screw counter-clockwise.

To turn rinse agent injector “OFF” in this case, turn the adjustment screw counter-clockwise until the pump stops turning.

Note: If a sodium Hypochlorite (Chlorine) based sanitizer at a minimum concentration of 50ppm in the final rinse is used, use chlorine test papers to verify and monitor the 50ppm chlorine level

MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06

Page 6

Image 7
Contents INSTALLATION & OPERATION C M A D I S H M A C H I N E S1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIAMODEL GL-C TABLE OF CONTENTS1.Receiving ReceivingSHIPPING WEIGHT Specifications2. Specifications FRAME DIMENSIONS3.2.Plumbing 3. InstallationInstructions 3.1.Electrical4. GLC Flow Diagram Flow Diagram5.2.Operating Instructions Operation5.Operation 5.1.Filling the Wash TankTo Adjust Rinse Agent Injector 5.3.Cleaning Instructions3.3.1. Daily Cleaning Instructions 3.3.2. Weekly Cleaning Instructions6.Maintenance Maintenance6.1. Troubleshooting Lack of pressure in rinse RD AO BT IU CR IC Electrical Diagram7. Electrical Diagram DR AO BT UI RC CI