| Title |
| Installation & Operation |
| Rev 1.00A | ||
|
|
|
|
|
|
|
|
|
|
| Model | EAH / EC Dishwasher |
|
| 01/26/04 | ||
|
|
|
|
|
|
|
|
|
| Quick service guide |
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
| TECHNICAL ISSUE |
| CAUSE | SOLUTION |
|
| ||
| Starts with doors open |
| Faulty #1 micro switch (start/stop) | Replace micro switch, P/N 00411.00 |
| |||
|
|
|
| Faulty door switch | Replace switch, P/N 00557.55 |
|
| |
|
|
|
| Faulty #1 micro switch (start/stop) | Replace micro switch, P/N 00411.00 |
| ||
| Continues cycle |
| Faulty start/fill switch | Replace switch, P/N 00421.40 |
|
| ||
|
|
|
| Faulty door switch | Replace door switch, P/N 00557.55 |
| ||
| Wash motor will not shut off |
| Delimer switch in wrong position | Switch to NORMAL position |
|
| ||
|
|
|
| Faulty motor contactor | Replace contactor, P/N 00404.82 |
| ||
|
|
|
| Faulty # 6 micro switch | Replace micro switch, P/N 00411.00 |
| ||
| Sanitizer pump does not run |
| Delimer switch in wrong position | Switch to NORMAL position |
|
| ||
|
|
|
| Faulty sanitizer pump motor | Replace sani motor, P/N 00416.00 |
| ||
|
|
|
|
| Clean and replace diaphragm, P/N |
| ||
|
|
|
| Debris inside water solenoid valve | 00706.00 |
|
|
|
| Water solenoid leaking |
| High water pressure on supply line | Decrease water pressure |
|
| ||
|
|
|
| Faulty water solenoid valve | Replace valve, P/N 00705.00 |
|
| |
|
|
|
| Leaking drain ball | Replace drain ball, P/N 00121.00 |
|
| |
| Does not fill or hold water in tank |
|
|
|
|
|
| |
|
|
|
| Faulty #4 micro switch (Fill) | Replace micro switch, P/N 00411.00 |
| ||
|
|
|
| Debris inside water solenoid valve or | Clean and replace diaphragm/valve, |
| ||
|
|
|
| Faulty valve | , P/N 00706.00, P/N 00705.00 |
|
| |
|
|
|
|
|
|
|
| |
|
|
|
| Worn internal vac. Brkr parts | Replace or clean parts, P/N |
|
| |
|
|
|
|
| 00735.00 |
|
|
|
| Vacuum breaker leaks |
| Faulty check valve | Replace check valve, P/N 00715.00 |
| |||
|
|
|
|
|
| |||
|
|
|
| Low incoming water pressure | Increase water pressure |
|
| |
| Only runs when start/fill switch is |
|
|
|
|
|
| |
| depressed |
| Faulty #1 micro switch (start/stop) | Replace micro switch, P/N 00411.00 |
| |||
|
|
|
|
| ||||
|
|
|
| Faulty Door switch | Replace door switch, P/N 00557.55 |
| ||
| Will not start/ nothing works |
| Wall breaker tripped | Reset breaker |
|
| ||
|
|
|
| Master on/off switch on machine turned | Reset or replace master switch, P/N |
| ||
|
|
|
| off, or faulty | 00433.00 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Faulty #2 Micro switch (cycle reset) | Replace micro switch, P/N 00411.00 |
| ||
| Runs, but none of the other functions |
|
|
|
|
|
| |
| engage |
| Faulty ice cube relay (yellow relay) | Replace relay, P/N 00631.00 |
|
| ||
|
|
|
|
|
| |||
|
|
|
| Faulty motor contactor | Replace contactor, P/N 00404.82 |
|
Page 13