| Title | Installation & Operation | Rev 1.00A |
|
|
|
|
| Model | EAH / EC Dishwasher | 01/26/04 |
|
|
|
|
6.Water Line
The model EAH & EC should plumbed with ½” hot water line. The time necessary to deliver water to the machine is controlled by the number four cam. This cam provides the serviceman with the opportunity to
7.Activating Machine
The machine is equipped with a prime switch to activate the peristaltic pump at any time the master switch is “ON”.
Following the completion of the installation, always fill the machine with water before the machine is started.
Hold the fill button until the water level is approximately ½” to ¾” below the overflow hole in the PVC standpipe. This water level should be approximately even with the bottom edge splash guard in sump area of machine.
Activate the prime switches for the three chemical pumps until the product is discharging into the sump.
To start the machine, close the doors and the machine will cycle automatically.
The amount of product delivered by each cam is controlled by changing the opening in each cam. When the micro switch rides down into the cam, the peristaltic pump motor begins to rotate. It will continue to rotate until it rides up out of the groove. Therefore, to extend the amount of product delivered to the machine, open the groove. To reduce the amount of product delivered to the machine, close the groove. Cams are slip fit. A cam adjustment wrench is provided, but the cam can be adjusted with a small screwdriver or the edge of a table knife.
Technical personnel are available during normal business hours should you, as an installer, have any questions. We are available to serve you at
Page 6