SOLUTION

 

Delimer switch in delime position

Flip to NORMAL position

Wash Pump motor will not shut off

Faulty delimer switch

Replace switch, P/N 00475.30

 

Faulty manual drain switch

Replace switch, P/N 03406.62

 

Faulty contactor

Replace contactor, P/N 00404.82

Continues cycles

Faulty #1 micro switch (start/stop)

Replace switch, P/N 00411.00

 

Faulty start/fill switch

Replace switch, P/N 03470.01

 

Faulty #1 micro switch

Replace switch, P/N 00411.00

 

 

Add water to tank to activate float switch, adjust

 

Low water level inside machine

water cam on timer

Sustainer heater not working

Faulty float switch

Replace switch, P/N 13463.10

 

Machine not level

Level machine

 

Faulty ice cube relay

Replace relay, P/N 00631.00

Machine does not drain

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

 

Faulty drain valve

Replace drain valve, P/N 04103.00

Does not hold water

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

 

Clogged or defective drain valve

Clean and/ or replace drain valve, P/N 04103.00

 

 

Clean and replace valve diaphragm, P/N

Tank overflows overnight

Debris in water Solenoid Valve

00707.00

 

Dirty or defective vacuum breaker kit

Clean or replace internal parts, P/N 03623.00

Water leaks out of Vacuum Breaker

assy

 

 

 

 

Faulty check valve

Replace check valve, P/N 00715.00

 

Male/ female plug on the back of control

Secure plug

 

drawer is loose

 

 

 

 

Wash Pump motor not running

Faulty door reed switch

Replace reed switch, P/N 00557.55

 

Faulty 7th micro switch

Replace switch, P/N 00411.00

 

Faulty motor contactor

Replace contactor, P/N 00404.82

 

Faulty Start/Fill Switch

Replace switch, P/N 03470.01

Timer does not rotate

Faulty #1 micro switch

Replace switch, P/N 00411.00

 

Faulty timer motor

Replace motor assembly, P/N 00501.00

 

Faulty #4 Micro switch

Replace switch, P/N 00411.00

 

Debris inside water solenoid valve or

Clean and replace valve diaphragm, P/N

 

Faulty valve

Machine does not fill

00707.00

 

 

Faulty water solenoid coil

Replace solenoid coil, P/N 00738.10

 

Delimer switch in wrong position

Switch to NORMAL position

Sanitizer pump does not run

Faulty 5th micro switch

Replace switch, P/N 00411.00

 

Faulty sanitizer pump motor

Replace motor, P/N 00416.00

0204

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01 –08/04/05

PAGE 11

Image 12
Contents Keep with machine for reference C M A D I S H M A C H I N E S1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIATABLE OF CONTENTS MODEL CMA-GL-X1. Specifications GL-XFRAME DIMENSIONS SHIPPING WEIGHT1.2.GL-XOperational Cycle WASHDRAIN RINSEPage Getting Started 2. Getting Started2.1.Introduction to the GL-X 2.2.Receiving and Installation Getting Started2.2.1. Electrical 2.2.2. PlumbingGlasswasher checked for concealed damage 3.1.Initial Setup Operation3.Operation 3.2.GeneralOperation 3.2.3. Proper Filling3.2.4. Water Pump 3.2.5. Pump CavitationMaintenance 4. Maintenance4.1.Timer assembly 4.1.1. Cam AdjustmentMaintenance 4.2.Quick service guideTECHNICAL ISSUE SOLUTION4.3.Troubleshooting Low heat during operation Activating detergent primer Addendum 3.Chlorine sanitizer must be a minimum of 100 PPMAppendix A Operator & Cleaning Instructions 6. Electrical Diagram Electrical DiagramWIRE DIAGRAM FOR MODEL GL-X BOOSTER HEATERWIRE DIAGRAM FOR MODEL GL-X Rev.1.02GROUND