4.2.Quick service guide
MODELS: GLX |
|
| |
TECHNICAL ISSUE | CAUSE | SOLUTION | |
| Delimer switch in delime position | Flip to NORMAL position | |
Wash Pump motor will not shut off | Faulty delimer switch | Replace switch, P/N 00475.30 | |
| Faulty manual drain switch | Replace switch, P/N 03406.62 | |
| Faulty contactor | Replace contactor, P/N 00404.82 | |
Continues cycles | Faulty #1 micro switch (start/stop) | Replace switch, P/N 00411.00 | |
| Faulty start/fill switch | Replace switch, P/N 03470.01 | |
| Faulty #1 micro switch | Replace switch, P/N 00411.00 | |
|
| Add water to tank to activate float switch, adjust | |
| Low water level inside machine | water cam on timer | |
Sustainer heater not working | Faulty float switch | Replace switch, P/N 13463.10 | |
| Machine not level | Level machine | |
| Faulty ice cube relay | Replace relay, P/N 00631.00 | |
Machine does not drain | Faulty #3 micro switch (drain) | Replace switch, P/N 00411.00 | |
| Faulty drain valve | Replace drain valve, P/N 04103.00 | |
Does not hold water | Faulty #3 micro switch (drain) | Replace switch, P/N 00411.00 | |
| Clogged or defective drain valve | Clean and/ or replace drain valve, P/N 04103.00 | |
|
| Clean and replace valve diaphragm, P/N | |
Tank overflows overnight | Debris in water Solenoid Valve | 00707.00 | |
| Dirty or defective vacuum breaker kit | Clean or replace internal parts, P/N 03623.00 | |
Water leaks out of Vacuum Breaker | assy |
| |
|
| ||
| Faulty check valve | Replace check valve, P/N 00715.00 | |
| Male/ female plug on the back of control | Secure plug | |
| drawer is loose |
| |
|
|
| |
Wash Pump motor not running | Faulty door reed switch | Replace reed switch, P/N 00557.55 | |
| Faulty 7th micro switch | Replace switch, P/N 00411.00 | |
| Faulty motor contactor | Replace contactor, P/N 00404.82 | |
| Faulty Start/Fill Switch | Replace switch, P/N 03470.01 | |
Timer does not rotate | Faulty #1 micro switch | Replace switch, P/N 00411.00 | |
| Faulty timer motor | Replace motor assembly, P/N 00501.00 | |
| Faulty #4 Micro switch | Replace switch, P/N 00411.00 | |
| Debris inside water solenoid valve or | Clean and replace valve diaphragm, P/N | |
| Faulty valve | ||
Machine does not fill | 00707.00 | ||
| |||
| Faulty water solenoid coil | Replace solenoid coil, P/N 00738.10 | |
| Delimer switch in wrong position | Switch to NORMAL position | |
Sanitizer pump does not run | Faulty 5th micro switch | Replace switch, P/N 00411.00 | |
| Faulty sanitizer pump motor | Replace motor, P/N 00416.00 |