Operation

Operation

3.Operation

3.1.Initial Setup

3.1.1.Check…

Drain screen is in place

Spay arms and end plugs are secure

3.1.2.Chemicals

Assure there is a sufficient supply of chemicals before beginning a shift.

3.1.3.Filling the Machine

With the power ON, press and hold the Fill/Start switch in the “FILL” position until the water level in the wash tank is about 1” deep, or just below the bottom wash arm.

3.2.General

Caution: Do not operate the dishmachine without the drain screen in place. Debris getting into the pump impeller can damage the pump.

1.Load a rack of glass into the machine and close the door.

2.With the machine filled to the proper level, press rocker Fill/Start switch to the “START” position – the machine will automatically begin its cycle. The green running light on the switch will illuminate while an operational cycle is in process.

3.At the end of the shift, drain the machine by holding the Drain rocker switch in the “DRAIN” position until the machine is completely drained. To avoid running the pump dry, do not hold the Drain rocker switch in the “DRAIN” position any longer than necessary.

4.Remove and clean the drain screen. Remove and clean the spray arms. (See wall chart instructions).

5.Replace the drain screen and spray arms.

3.2.1. Pre-Scrapping

It is essential that the operator thoroughly understand the importance of pre-scrapping the glasses before loading them. The GL-X is equipped with a removable drain screen. The drain screen can be easily removed for cleaning between Operational Cycles of the dishmachine. Properly pre-scrapping the glasses should permit the glasswasher to operate for an entire shift before needing to remove and clean the drain screen.

3.2.2. Proper Chemical Dosage

The amount of chemical delivered, whether it is detergent, sanitizer or rinse aid, is determined by its respective cam on the cam timer.

Cam number 2 runs the detergent pump

Cam number 5 runs the sanitizer pump

Cam number 6 runs the rinse aid pump

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01 –08/04/05

PAGE8

Image 9
Contents C M A D I S H M A C H I N E S Keep with machine for reference1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIAMODEL CMA-GL-X TABLE OF CONTENTSGL-X 1. SpecificationsFRAME DIMENSIONS SHIPPING WEIGHTWASH 1.2.GL-XOperational CycleDRAIN RINSEPage Getting Started 2. Getting Started2.1.Introduction to the GL-X Getting Started 2.2.Receiving and Installation2.2.1. Electrical 2.2.2. PlumbingGlasswasher checked for concealed damage Operation 3.1.Initial Setup3.Operation 3.2.General3.2.3. Proper Filling Operation3.2.4. Water Pump 3.2.5. Pump Cavitation4. Maintenance Maintenance4.1.Timer assembly 4.1.1. Cam Adjustment4.2.Quick service guide MaintenanceTECHNICAL ISSUE SOLUTION4.3.Troubleshooting Low heat during operation Activating detergent primer 3.Chlorine sanitizer must be a minimum of 100 PPM AddendumAppendix A Operator & Cleaning Instructions Electrical Diagram 6. Electrical DiagramWIRE DIAGRAM FOR MODEL GL-X BOOSTER HEATERWIRE DIAGRAM FOR MODEL GL-X Rev.1.02GROUND