CMA Dishmachines GL-X owner manual Getting Started, Glasswasher checked for concealed damage

Page 8
Glasswasher checked for concealed damage

Getting Started

2.2.4. Installers Checklist

Glasswasher checked for concealed damage

Hot water supply is recommended 140° F (60 C)

Incoming water supply line is ½” minimum

Supply circuit breaker for machine is properly sized (20 amp) Service voltage and phase type are correct to machine data plate Drain hose is installed with adequate air gap

Glasswasher is properly grounded

Glasswasher is properly leveled

Machine circuit breaker is labeled “GLASSWASHER”

Machine has been connected with correctly sized wire (To handle 20 amp)

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01 –08/04/05

PAGE 7

Image 8
Contents Keep with machine for reference C M A D I S H M A C H I N E S1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIATABLE OF CONTENTS MODEL CMA-GL-X1. Specifications GL-XFRAME DIMENSIONS SHIPPING WEIGHT1.2.GL-XOperational Cycle WASHDRAIN RINSEPage 2.1.Introduction to the GL-X Getting Started2. Getting Started 2.2.Receiving and Installation Getting Started2.2.1. Electrical 2.2.2. PlumbingGlasswasher checked for concealed damage 3.1.Initial Setup Operation3.Operation 3.2.GeneralOperation 3.2.3. Proper Filling3.2.4. Water Pump 3.2.5. Pump CavitationMaintenance 4. Maintenance4.1.Timer assembly 4.1.1. Cam AdjustmentMaintenance 4.2.Quick service guideTECHNICAL ISSUE SOLUTION4.3.Troubleshooting Low heat during operation Activating detergent primer Addendum 3.Chlorine sanitizer must be a minimum of 100 PPMAppendix A Operator & Cleaning Instructions 6. Electrical Diagram Electrical DiagramWIRE DIAGRAM FOR MODEL GL-X BOOSTER HEATERGROUND WIRE DIAGRAM FOR MODEL GL-XRev.1.02
Related manuals
Manual 19 pages 5.09 Kb