3.2.Beginning Operation

To run the dishmachine, perform the following steps:

1. Close both drains (valve handles in vertical position).

 

 

 

CLOSE

 

CLOSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Turn on the power to the dishmachine. The machine will begin its (adjustable) timed auto-fill. The float when sensing adequate water level energizes an ice cube relay, which will allow power to go to the heater while the door is closed and the water temperature is below the thermostat setting.

3.The temperature of the water in the tank should be 140°F – 150°F. The Tank heater will maintain a minimum temperature of 140° F if the final rinse is providing 140°F – 150°F at all times (CMA-44L). 150°F minimum will be maintained if the final rinse is 180°F – 195°F (CMA-44H).

If the thermostat (located behind the stainless steel cover on the final rinse side of the machine) should need adjustment—there is a thermostat adjustment access hole located on the cover.

Tip: If you are having difficulty maintaining wash tank temperature, minimize the vent hood openings by closing off the dampers.

4.Be sure to place the dishes correctly. If they become dislodged, they could interfere with the trip switch lever and interrupt the operation of the machine.

RACK TRAVEL

MODEL CMA-44 Installation & Operation Manual Rev. 2 .15 10/18/07

Page 15

Image 16
Contents Page Table of Contents Specifications CMA-44Getting Started Introduction to CMA-44Receiving and Installation Dishmachine Front ViewReceiving and Installation Old Models Electrical Installation NotesPlumbing Rinse Pressure Regulator for detailed instructions Scrap Tray Assembly and Overflow Chute Installation REQ’DInstallation Pump Impeller NoteOptional Hood Adapter Set of Two Optional Freestanding Scrap Trap and Adaptor Kit Field Installed Accessories CMA-44 HeaterSafety Tips for the CMA-44 Initial Setup Auto Fill Timer/ Auto Re- Fill TimerAuto Fill Timer Old Models Wash Tank TemperatureBeginning Operation Low Temperature Applications Chemical DispensingRegular Service and Maintenance Checklist Operation Quick service guide Models CMA 44/66 Conveyor S Technical Issue Cause SolutionTrouble Shooting Problem Likely Cause SolutionCMA-44 Customer Notice Tips to Save a Service Charge Electrical Diagram Electrical Diagram Old Models