CMA Dishmachines CMA-44 manual Scrap Tray Assembly and Overflow Chute Installation, Req’D

Page 9

Getting Started

2.3.4. Scrap Tray Assembly and Overflow Chute Installation

The scrap tray assembly and overflow chute, which came packaged inside the machine, can easily be installed by executing the following steps: Figure 2.3.4 below illustrates the assembly as it would appear for a Left-to-Right machine – a Right-to- Left machine would simply be the mirror image.

Caution: For proper spacing, the

SSflat washer (item 2) must not be located between the head of the trusshead bolt and the inside of the machine.

Figure 2.2.4

ITEM

NO.

P/N

 

DESCRIPTION

NO.

REQ’D

 

 

 

 

 

 

 

 

1

7

00905.00

¼-20 X ½” Trusshead Bolt

 

 

 

 

2

11

00924.00

¼” SS Flat Washer

 

 

 

 

3

11

00912.00

¼-20 Nylon Lock Nut

4

1

13511.26

CMA-44P

Overflow Gasket

5

1

13511.06

CMA-44P

Overflow Chute (L-R)

 

 

13511.16

CMA-44P

Overflow Chute (R-L)

 

 

 

 

 

ITEM

NO.

P/N

DESCRIPTION

NO.

REQ’D

 

 

 

 

 

¼-20 X ½” Hex Head Bolt

6

4

00906.00

 

 

 

Scrap Trap Holder

7

1

17579.00

 

 

 

Scrap Trap Body Molded

8

1

01577.10

9

1

01577.20

Scrap Trap Drawer Molded

1.Remove the items from their packing and verify that all the pieces are present.

2.Attach the overflow chute with the five ¼-20 X ½” trusshead bolts, ¼” SS Flat Washers, and ¼-20 Nylon Lock Nuts provided.

3.Secure the scrap trap holder to the dishmachine using the four ¼-20 X ½” Hex Head Bolts, ¼” SS Flat Washers, and ¼-20 Nylon Lock Nuts provided.

4.Set the scrap trap body—with the scrap trap drawer inserted—into position on the scrap trap holder.

5.Attach the drain as specified in section 2.3.2 Plumbing.

MODEL CMA-44 Installation & Operation Manual Rev. 2 .15 10/18/07

Page 8

Image 9
Contents Page Table of Contents CMA-44 SpecificationsIntroduction to CMA-44 Getting StartedDishmachine Front View Receiving and InstallationReceiving and Installation Old Models Installation Notes ElectricalPlumbing Rinse Pressure Regulator for detailed instructions REQ’D Scrap Tray Assembly and Overflow Chute InstallationPump Impeller Note InstallationOptional Hood Adapter Set of Two Optional Freestanding Scrap Trap and Adaptor Kit CMA-44 Heater Field Installed AccessoriesSafety Tips for the CMA-44 Auto Fill Timer/ Auto Re- Fill Timer Initial SetupAuto Fill Timer Old Models Wash Tank TemperatureBeginning Operation Chemical Dispensing Low Temperature ApplicationsRegular Service and Maintenance Checklist Operation Models CMA 44/66 Conveyor S Technical Issue Cause Solution Quick service guideProblem Likely Cause Solution Trouble ShootingCMA-44 Customer Notice Tips to Save a Service Charge Electrical Diagram Electrical Diagram Old Models