York R-410A ZH/ZJ/ZR Series Guide Specifications, Accessories Continued, General, Description

Models: R-410A ZH/ZJ/ZR Series

1 206
Download 206 pages 7.86 Kb
Page 12
Image 12
Field Installed Acessories - Fresh Air

528150-YTG-G-1210

Accessories (Continued)

Field Installed Acessories - Fresh Air

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

 

All

Barometric Relief Kit for Power Exhaust, Downflow

 

1EH0407

Application (Includes Hood)

All Cabinets

 

 

 

Barometric Relief Kit for Power Exhaust, Horizontal

 

1EH0408

All

Application

All Cabinets

 

 

Barometric Relief/Hood Kit - Required for field installed

 

1EH0409

All

slab economizer without ERV

All Cabinets

1FA0413

All

Manual Outside Air Damper 0-35%, Downflow

All Cabinets

1FA0414

All

Manual Outside Air Damper 0-100%, Downflow

All Cabinets

1RD0411

All

Barometric Relief Kit for Horizontal Applications

All Cabinets

2EC04700924

All

Dual Enthalpy Control

All Cabinets

 

 

Downflow Economizer, Slab type for ERV, (no

 

2EE04705724

All

Barometric Relief or FA hood)

All 50" Cabinets

 

 

Downflow Economizer, Slab type for ERV, (no

 

2EE04705824

All

Barometric Relief or FA hood)

All 42" Cabinets

2EE04705924

All

Downflow Economizer with Barometric Relief

All Cabinets

2EE04706024

All

Horizontal Economizer without Barometric Relief

All Cabinets

2MD04703224

All

Motorized Damper, Downflow without Barometric Relief

All Cabinets

2MD04703724

All

Motorized Damper, Horizontal

All Cabinets

2PE04703225*

230

Power Exhaust 230V Downflow or Horizontal

All Cabinets

2PE04703246*

460

Power Exhaust 460V Downflow or Horizontal

All Cabinets

2PE04703258*

575

Power Exhaust 575V Downflow or Horizontal

All Cabinets

* Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required.

Field Installed Acessories - Controls

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

2AP0401

All

Air Proving Switch

All Units

2AQ04700324B

All

CO² Space Accessory

All Units

2AQ04700424C

All

CO² Unit Accessory

All Units

2DF0402

All

Dirty Air Switch

All Units

2DH04700024

All

Humidistat

All Units

 

 

 

All Gen 4 or older units with 2" Filter only capable

2SD04700624

All

Smoke Detector for Supply or Return

Cabinets

2SD04700824

All

Smoke Detector for Supply

All Gen 5 units with 2" & 4" Filters

2SD04700924

All

Smoke Detector for Return

All Gen 5 units with 2" & 4" Filters

2SD04701024

All

Smoke Detector for Supply and Return

All Gen 5 units with 2" & 4" Filters

Field Installed Acessories - Electrical

MODEL

VOLTAGE

DESCRIPTION

WHERE USED

2BC04700106

230

Gas heat kit, -60ºF

All Units

2BC04700151

460

Gas heat kit, -60ºF

All Units

2BC04700154

575

Gas heat kit, -60ºF

All Units

2LA04704632

All

Low Ambient Kit

All 3

- 10T units (excludes 12.5T "V" cabinets)

2LA04704634

All

Low Ambient Kit

All 3

- 5T Reheat Units (Only)

Guide Specifications

GENERAL

Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 3 through 12-1/2 ton models. All 6-1/2 through 12-1/2 ton units have two compressors with independent R- 410A refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged with R-410A, wired, piped, and tested at the factory to provide a quick and easy

field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, reheat only, reheat with electric heat and reheat with gas heat. Electric heaters are available as factory-installed options or field-installed accessories.

DESCRIPTION

Units shall be factory assembled, single package, (Elec/Elec, Gas/ Elec), designed for outdoor installation. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be

12

Johnson Controls Unitary Products

Page 12
Image 12
York R-410A ZH/ZJ/ZR Series Guide Specifications, Accessories Continued, Field Installed Acessories - Fresh Air, General