York R-410A ZH/ZJ/ZR Series manual YTG-G-1210, Gas Heat Minimum Supply Air

Models: R-410A ZH/ZJ/ZR Series

1 206
Download 206 pages 7.86 Kb
Page 103
Image 103
Gas Heat Minimum Supply Air

528150-YTG-G-1210

Gas Heat Minimum Supply Air

Size

 

 

Supply Air (CFM)

Model

Heat Size

 

Heating

(Tons)

 

 

 

Min

 

Max

 

 

 

 

037

 

A05 / N05

890

 

2220

ZH/ZJ/ZR

A07 / N07

915

 

2370

(3)

 

 

A09 / N09

1130

 

1800

 

 

 

049

 

A05 / N05

890

 

2220

ZH/ZJ/ZR

A07 / N07

915

 

2370

(4)

 

 

A09 / N09

1290

 

2250

 

 

 

061

 

A07 / N07

915

 

2370

ZH/ZJ/ZR

A09 / N09

1380

 

2570

(5)

 

 

A13 / N13

1580

 

2630

 

 

 

078

ZH/ZJ/ZR

10

1950

 

3250

(6.5)

15

1950

 

3250

 

 

090

ZH/ZJ/ZR

10

2250

 

3750

(7.5)

15

2250

 

3750

 

 

102

ZH/ZJ/ZR

10

2550

 

4250

(8.5)

15

2550

 

4250

 

 

120

ZH/ZJ/ZR

15

3000

 

5000

(10)

20

3000

 

5000

 

 

150

ZH/ZJ/ZR

15

3750

 

6250

(12.5)

20

3750

 

6250

 

 

Electric Heat Minimum Supply Air 3 thru 5 Tons

Size

 

 

 

 

 

Minimum Supply Air (CFM)

 

 

 

Model

Voltage

 

 

 

Heater kW

 

 

 

(Tons)

 

 

 

 

 

 

 

 

 

 

3

6

 

9

 

15

20

24

 

 

 

 

 

 

037

 

 

208/230-3-60

960

960

 

1020

 

1020

-

-

 

ZH/ZJ/ZR

460-3-60

980

960

 

960

 

960

-

-

(3)

 

 

 

 

 

600-3-60

-

-

 

960

 

960

-

-

 

 

 

 

 

049

 

 

208/230-3-60

-

1280

 

1420

 

1420

1420

-

 

ZH/ZJ/ZR

460-3-60

-

1400

 

1400

 

1400

1400

-

(4)

 

 

 

 

 

600-3-60

-

-

 

1400

 

1400

1400

-

 

 

 

 

 

061

 

 

208/230-3-60

-

1600

 

1600

 

1600

1600

1600

 

ZH/ZJ/ZR

460-3-60

-

1600

 

1600

 

1600

1600

1600

(5)

 

 

 

 

 

600-3-60

-

-

 

1600

 

1600

1600

1600

 

 

 

 

 

6-1/2 thru 12-1/5 Tons

 

 

 

 

 

 

 

 

 

 

Size

 

 

 

 

Minimum Supply Air (CFM)

 

 

 

Model

Voltage

 

 

 

Heater kW

 

 

 

(Tons)

 

 

 

 

 

 

 

 

 

 

9

18

 

24

 

36

54

 

 

 

 

 

 

 

 

078

 

 

208/230-3-60

1950

1950

 

1950

 

1950

-

 

 

ZH/ZJ/ZR

460-3-60

1950

1950

 

1950

 

1950

-

 

(6.5)

 

 

 

 

 

 

600-3-60

1950

1950

 

1950

 

1950

-

 

 

 

 

 

 

 

090

 

 

208/230-3-60

2250

2250

 

2250

 

2250

-

 

 

ZH/ZJ/ZR

460-3-60

2250

2250

 

2250

 

2250

-

 

(7.5)

 

 

 

 

 

 

600-3-60

2250

2250

 

2250

 

2250

-

 

 

 

 

 

 

 

102

 

 

208/230-3-60

2550

2550

 

2550

 

2550

-

 

 

ZH/ZJ/ZR

460-3-60

2550

2550

 

2550

 

2550

-

 

(8.5)

 

 

 

 

 

 

600-3-60

2550

2550

 

2550

 

2550

-

 

 

 

 

 

 

 

120

 

 

208/230-3-60

-

3000

 

3000

 

3000

3500

 

 

ZH/ZJ/ZR

460-3-60

-

3000

 

3000

 

3000

3000

 

(10)

 

 

 

 

 

 

600-3-60

-

3000

 

3000

 

3000

3500

 

 

 

 

 

 

 

150

 

 

208/230-3-60

-

3750

 

3750

 

3750

4000

 

 

ZH/ZJ/ZR

460-3-60

-

3750

 

3750

 

3750

3750

 

(12.5)

 

 

 

 

 

 

600-3-60

-

3750

 

3750

 

3750

3750

 

 

 

 

 

 

 

Johnson Controls Unitary Products

103

Page 103
Image 103
York R-410A ZH/ZJ/ZR Series manual YTG-G-1210, Gas Heat Minimum Supply Air, Electric Heat Minimum Supply Air 3 thru 5 Tons