ZJ078 (6.5 Ton) (Continued)

528150-YTG-G-1210

ZJ078 (6.5 Ton) (Continued)

Air on

 

 

 

 

 

 

Temperature of Air on Condenser Coil

 

 

 

 

 

 

Evaporator Coil

Total

Total

 

Sensible Capacity (MBh)

 

Total

Total

 

Sensible Capacity (MBh)

 

CFM

 

WB

Capacity1

Input

 

Return Dry Bulb (°F)

 

Capacity1

Input

 

Return Dry Bulb (°F)

 

 

(°F)

(MBh)

(kW)2

 

 

 

 

 

 

(MBh)

(kW)2

 

 

 

 

 

 

 

90

85

80

75

70

65

90

85

80

75

70

65

 

 

 

 

 

 

115°F

 

 

 

 

 

 

 

125°F

 

 

 

 

 

 

77

72.1

6.8

27.6

25.3

18.8

-

-

-

63.3

7.3

26.5

21.1

16.1

-

-

-

1625

 

72

64.6

6.6

41.6

35.1

28.6

22.1

-

-

56.2

7.1

37.8

31.6

25.4

19.2

-

-

 

67

57.2

6.4

55.6

44.9

38.4

31.9

25.4

-

49.1

6.9

49.1

40.9

34.7

28.5

22.3

-

 

 

 

 

62

50.7

6.3

50.7

50.7

42.5

36.0

29.5

23.0

43.2

6.8

43.2

43.2

37.2

31.0

24.8

18.6

 

 

77

75.3

6.8

36.7

28.9

21.1

-

-

-

66.8

7.4

36.3

25.9

18.4

-

-

-

 

 

72

67.5

6.6

47.7

39.9

32.1

24.3

-

-

59.3

7.2

44.1

36.5

29.0

21.4

-

-

1950

 

67

59.8

6.5

58.7

50.9

43.1

35.3

27.5

-

51.8

7.0

51.8

47.1

39.6

32.1

24.5

-

 

 

62

53.0

6.4

53.0

53.0

47.8

40.0

32.2

24.4

45.6

6.8

45.6

45.6

42.5

34.9

27.4

19.8

 

 

57

56.6

6.4

56.6

56.6

49.6

41.8

34.0

26.2

52.3

6.9

52.3

52.3

43.4

35.9

28.4

20.8

 

 

77

78.5

6.8

45.8

32.5

23.4

-

-

-

70.2

7.4

46.1

30.7

20.7

-

-

-

 

 

72

70.4

6.7

53.8

44.7

35.6

26.6

-

-

62.4

7.2

50.3

41.5

32.6

23.7

-

-

2275

 

67

62.3

6.5

61.8

56.9

47.8

38.8

29.7

-

54.6

7.0

54.6

53.4

44.5

35.6

26.7

-

 

 

62

55.3

6.4

55.3

55.3

53.0

43.9

34.9

25.8

48.0

6.8

48.0

48.0

47.8

38.9

30.0

21.1

 

 

57

59.1

6.4

59.1

59.1

55.0

46.0

36.9

27.8

55.0

6.9

55.0

55.0

48.9

40.0

31.1

22.2

 

 

77

81.7

6.9

54.9

36.1

25.7

-

-

-

73.7

7.5

56.0

35.5

23.0

-

-

-

 

 

72

73.3

6.7

59.9

49.5

39.2

28.8

-

-

65.5

7.2

56.6

46.4

36.2

25.9

-

-

2600

 

67

64.9

6.6

64.9

62.9

52.6

42.2

31.9

-

57.3

7.0

57.3

57.3

49.4

39.1

28.9

-

 

 

62

57.5

6.4

57.5

57.5

58.3

47.9

37.5

27.2

50.4

6.9

50.4

50.4

50.4

42.8

32.6

22.3

 

 

57

61.5

6.5

61.5

61.5

60.5

50.1

39.7

29.4

57.6

7.0

57.6

57.6

54.3

44.1

33.8

23.6

 

 

72

74.5

6.7

63.6

52.5

41.4

30.3

-

-

66.4

7.3

59.9

49.0

38.1

27.2

-

-

2925

 

67

65.9

6.6

65.9

65.0

55.6

44.5

33.4

-

58.0

7.1

58.0

58.0

52.0

41.1

30.2

-

 

62

58.5

6.5

58.5

58.5

58.8

47.7

36.6

25.5

51.1

6.9

51.1

51.1

51.1

41.5

30.6

19.6

 

 

 

 

57

62.5

6.5

62.5

62.5

62.0

50.9

39.8

28.7

58.4

7.0

58.4

58.4

56.8

45.8

34.9

24.0

 

 

72

75.7

6.8

67.3

55.4

43.6

31.8

-

-

67.2

7.3

63.2

51.6

40.0

28.4

-

-

3250

 

67

67.0

6.6

67.0

67.0

58.5

46.7

34.9

-

58.8

7.1

58.8

58.8

54.7

43.1

31.5

-

 

62

59.4

6.5

59.4

59.4

59.4

47.6

35.8

23.9

51.7

7.0

51.7

51.7

51.7

40.1

28.5

16.9

 

 

 

 

57

63.5

6.5

63.5

63.5

63.5

51.7

39.8

28.0

59.2

7.1

59.2

59.2

59.2

47.6

36.0

24.4

1.These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.