ZH102 (8.5 Ton) (Continued)

528150-YTG-G-1210

ZH102 (8.5 Ton) (Continued)

Air on

 

 

 

 

 

 

Temperature of Air on Condenser Coil

 

 

 

 

 

 

Evaporator Coil

Total

Total

 

Sensible Capacity (MBh)

 

Total

Total

 

Sensible Capacity (MBh)

 

CFM

 

WB

Capacity1

Input

 

Return Dry Bulb (°F)

 

Capacity1

Input

 

Return Dry Bulb (°F)

 

 

(°F)

(MBh)

(kW)2

 

 

 

 

 

 

(MBh)

(kW)2

 

 

 

 

 

 

 

90

85

80

75

70

65

90

85

80

75

70

65

 

 

 

 

 

 

115°F

 

 

 

 

 

 

 

125°F

 

 

 

 

 

 

77

101.7

9.7

38.8

35.0

25.9

-

-

-

91.0

10.3

34.9

30.1

22.7

-

-

-

2125

 

72

92.3

9.4

58.1

49.0

39.9

30.8

-

-

82.4

10.0

54.4

45.4

36.5

27.5

-

-

 

67

82.9

9.1

77.4

63.0

53.9

44.8

35.7

-

73.8

9.7

73.8

59.2

50.2

41.3

32.3

-

 

 

 

 

62

78.3

8.9

78.3

78.3

62.9

53.8

44.7

35.6

71.2

9.5

71.2

71.2

56.5

47.6

38.6

29.7

 

 

77

103.6

9.7

49.8

39.2

28.6

-

-

-

92.7

10.4

48.3

35.8

25.3

-

-

-

 

 

72

94.1

9.4

65.3

54.7

44.1

33.5

-

-

83.9

10.1

61.7

51.1

40.5

30.0

-

-

2550

 

67

84.5

9.2

80.8

70.2

59.6

49.0

38.3

-

75.2

9.7

75.2

66.4

55.8

45.2

34.7

-

 

 

62

79.7

9.0

79.7

79.7

69.5

58.9

48.3

37.6

72.4

9.6

72.4

72.4

62.9

52.3

41.7

31.2

 

 

57

79.2

9.0

79.2

78.8

68.2

57.6

46.9

36.3

72.9

9.6

72.9

72.3

58.4

47.8

37.2

26.6

 

 

77

105.6

9.8

60.8

43.4

31.3

-

-

-

94.3

10.5

61.6

41.6

27.8

-

-

-

 

 

72

95.8

9.5

72.5

60.4

48.2

36.1

-

-

85.4

10.2

69.0

56.8

44.6

32.4

-

-

2975

 

67

86.1

9.2

84.3

77.4

65.2

53.1

40.9

-

76.5

9.8

76.5

73.6

61.4

49.2

37.0

-

 

 

62

81.2

9.0

81.2

81.2

76.1

63.9

51.8

39.7

73.7

9.6

73.7

73.7

69.2

57.0

44.9

32.7

 

 

57

80.7

9.1

80.7

80.5

74.6

62.5

50.3

38.2

74.2

9.7

74.2

73.9

64.3

52.1

39.9

27.7

 

 

77

107.5

9.8

71.8

47.6

34.0

-

-

-

95.9

10.6

74.9

47.3

30.4

-

-

-

 

 

72

97.6

9.6

79.7

66.1

52.4

38.7

-

-

86.8

10.2

76.3

62.5

48.7

34.9

-

-

3400

 

67

87.7

9.3

87.7

84.5

70.9

57.2

43.5

-

77.8

9.9

77.8

77.8

67.0

53.2

39.4

-

 

 

62

82.7

9.1

82.7

82.7

82.7

69.0

55.3

41.7

75.0

9.7

75.0

75.0

75.0

61.8

48.0

34.2

 

 

57

82.1

9.1

82.1

82.1

81.1

67.4

53.7

40.1

75.4

9.8

75.4

75.4

70.3

56.5

42.6

28.8

 

 

72

96.2

9.6

85.3

70.4

55.4

40.5

-

-

83.7

10.3

81.4

66.4

51.4

36.4

-

-

3825

 

67

86.4

9.3

86.4

84.8

74.9

60.0

45.0

-

74.9

9.9

74.9

74.9

70.8

55.8

40.8

-

 

62

81.5

9.2

81.5

81.5

81.5

66.5

51.6

36.6

72.3

9.8

72.3

72.3

72.3

57.6

42.6

27.6

 

 

 

 

57

80.9

9.2

80.9

80.9

80.4

65.5

50.5

35.6

72.8

9.8

72.8

72.8

70.2

55.2

40.2

25.2

 

 

72

94.7

9.7

90.9

74.7

58.4

42.2

-

-

80.5

10.3

80.5

70.3

54.1

38.0

-

-

4250

 

67

85.1

9.4

85.1

85.1

79.0

62.8

46.5

-

72.1

10.0

72.1

72.1

72.1

58.3

42.2

-

 

62

80.3

9.2

80.3

80.3

80.3

64.1

47.8

31.6

69.7

9.8

69.7

69.7

69.7

53.5

37.3

21.1

 

 

 

 

57

79.7

9.2

79.7

79.7

79.7

63.5

47.3

31.0

70.2

9.9

70.2

70.2

70.2

54.0

37.8

21.7

1.These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.

2.These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

46

Johnson Controls Unitary Products

Page 46
Image 46
York R-410A ZH/ZJ/ZR Series manual ZH102 8.5 Ton Continued, Johnson Controls Unitary Products