SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
AUSTRALIAN REQUIREMENTS:
To be installed on a firm, level surface in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. The Australian orifice size and manifold pressures are listed below for the SR62.
Model | Gas Type | Orifice Size | Manifold Pressure KPa |
SR62 | Nat | 2.53 mm | 0.9 KPa |
SR62 | Prop | 1.6 mm | 2.4 KPa |
CE UNITS ONLY:
Manifold Pressure Inches WC 3.6” 9.6”
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings and Pilot Markings are listed in the table below:
| NOMINAL |
| ORIFICE | MANIFOLD GAS PRESSURE | ORIFICE | BURNER | PILOT | ||
MODEL* | HEAT INPUT- | GAS TYPE | |||||||
|
| ||||||||
| Qn |
| SIZE (MM) | MBAR | INCH W.C. | QTY/ COLOR | MARKING | MARKING | |
| (kW) |
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
|
| G20 | 2.40 | 12,0 | 4,8 | 5/BLUE | Blue | 26N | |
SR62 GM | 37.5 | G25 | 2.40 | 17,5 | 7,0 | 5/BLUE | Blue | 26N | |
|
| G31 | 1.51 | 22,0 | 8,8 | 5/RED | Red | 16LP | |
SR52 GM | 30 | G20 | 2.40 | 12,0 | 4,8 | 4/BLUE | Blue | 26N | |
G25 | 2.40 | 17,5 | 7,0 | 4/BLUE | Blue | 26N | |||
|
| G31 | 1.51 | 22,0 | 8,8 | 4/RED | Red | 16LP | |
|
| G20 | 2.40 | 12,0 | 4,8 | 3/BLUE | Blue | 26N | |
SR42 GM | 26 | G25 | 2.40 | 17,5 | 7,0 | 3/BLUE | Blue | 26N | |
|
| G31 | 1.51 | 22,0 | 8,8 | 3/RED | Red | 16LP |
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are listed in the table below:
| NOMINAL |
|
| MANIFOLD GAS |
|
| |
| HEAT INPUT- |
| ORIFICE | ORIFICE | PILOT | ||
MODEL* | GAS TYPE | PRESSURE | |||||
| Qn |
| SIZE (MM) | (INCH W.C.) | QUANTITY | MARKING | |
| (BTU) |
|
|
|
| ||
|
|
|
|
|
| ||
SR62 GM | 150 | NAT | 2.53(#39) | 4 | 5 | 26N | |
LP | 1.51(#53) | 11 | 5 | 16LP | |||
|
| ||||||
SR52 GM | 120 | NAT | 2.53(#39) | 4 | 4 | 26N | |
LP | 1.51(#53) | 11 | 4 | 16LP | |||
|
| ||||||
SR42 GM | 105 | NAT | 2.80(#35) | 4 | 3 | 26N | |
LP | 1.70(#51) | 11 | 3 | 16LP | |||
|
|
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
1.4Connection to the Gas Supply Line
NOTE: The gas supply (service) line must be the same size or greater than the fryer inlet line. This appliance is equipped with a
mm)inlet. The gas supply line must be sized to accommodate all gas- fired equipment connected to the line. Consult the local gas company or supplier, or your local contractor for minimum supply line requirements.
NOTE: If
Propane Applications;
Proper Regulator Must Be Installed