I INTRODUCTION
GENERAL
Keating Electric Custom Pasta™ Systems are designed to give maximum production efficiency, delivering high quality food products. The following design features are incorporated in Keating Pasta Electric Systems.
STANDARD FEATURES
•Highly polished stainless steel vessel
•Highly polished stainless steel front
•Highly polished stainless steel elements
•Highly polished stainless steel thermostat bulb
•Highly polished stainless steel
•Grid screen over elements
•Automatic water fill with manual override
•Water solenoid and indicating light
•Starch overflow
•Two electronic timers
•Low water safety shutoff
• 1" full port front drain valve on 14; 11/4" for 18 and larger
•High temperature limit control with manual reset
•Patented accurate temperature control system ±2°F
•Ideal 35" working height
•One pair of split baskets or one perforated basket
•Patented dual thermostat system
•Indicating lights for pilot and secondary thermostat on
STANDARD ACCESSORIES
•Keating Klenzer Sample
•Keating Sea Powder Sample
•Drain clean out rod
•Sensor Cleaning Brush
STANDARD PASTA SYSTEMS
•Sizes: 14 to 24
•Water capacity 51/2 to 171/2 gallons
•24 Pasta System can cook 6 lbs. of dry pasta per load up to 110 lbs. per hour
•NSF certified
•ETL Certified listed
•ETL Sanitation Certified listed
MODEL VARIATIONS
SPECIFICATIONS
MODEL | CAPACITY | HEIGHT | DEPTH | WIDTH |
|
|
|
|
|
14 | 7 gal. | 461/2" | 311/8" | 153/8" |
|
|
|
|
|
18 | 10 gal. | 461/2" | 331/8" | 193/8" |
|
|
|
|
|
20 | 15 gal. | 461/2" | 351/8" | 213/8" |
|
|
|
|
|
24 | 19 gal. | 461/2" | 391/8" | 253/8" |
|
|
|
|
|
|
|
|
|
|
MODEL | kW @ 240V | AMPS | SHIP WT. | |
|
| |||
|
| 3P | 1P |
|
|
|
|
|
|
14 | 15.5 | 65 | 125 lbs | |
|
|
|
|
|
18 | 20.7 | 87 | 175 lbs. | |
|
|
|
|
|
20 | 20.7 | 87 | 200 lbs. | |
|
|
|
|
|
24 | 28.6 | 119 | 300 lbs. | |
|
|
|
|
|
SAFETY
PRECAUTIONS
THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR OTHER INJURIES MAY RESULT IF SAFETY INSTRUCTIONS ARE NOT FOLLOWED.
•This service manual should be retained in a safe place for future reference. The installation of your new Pasta System must conform to local codes and with the current National Electrical Codes and regulations as applicable.
•Your ventilation hood, when installed, must conform to the current standards.
•No frame or restriction shall be constructed around the Custom Pasta System that will restrict air movement into the Pasta System or prevent proper ventilation.
•You must maintain this appliance free and clear from combustibles.
•Adequate clearance for servicing and proper operation must be maintained. Your pasta system is designed to be serviced from the front.