Select Clean
When Select Clean begins the cleaning cycle, the
motorized door latch mechanism will automatically start to
loci< the oven door and the DOOR LOCKED indicator light will flash. DO NOT open the oven door when the DOOR LOCKED indicator light is flashing. Allow about 15 seconds
for the oven door to completely loci<.
Once the oven door has locked the DOOR LOCKED indicator light will glow steady. When CLn will appears in the display Select Clean is active.
Use caution when opening the oven door after
When Select Cleon is finished:
1.The time of day will appear in the display window and the Select Clean and DOOR LOCKED indicator lights will continue to glow.
2.Once the oven has cooled down (about 1 hour) and the DOOR LOCI<ED indicator light has turned off the oven door may be opened.
3.When the oven interior has completely cooled, wipe away any residue or powdered ash with a damp cloth or paper towel.
Importont notes:
*The kitchen area should be well ventilated using an open window, ventilation fan or exhaust hood during the 1st
DO NOT attempt to open the oven door when the DOOR LOCKED indicator light is flashing. Allow about 15 seconds for the motorized door latch mechanism to completely lock or unlock the oven door.
When the clean time finishes the oven door will remain locked until the range has cooled sufficiently. In addition to the clean time that was programmed, you must allow about 1 additional hour for the oven to cool before you will be able to open the oven door.
*The Select Clean function will not operate when oven lockout is active.
if it becomes necessary to stop Select Clean when octlve:
1.Press STOP.
2.IfSelectClean has heated the oven to a high temperature, allow enough time forthe oven to cool and for the DOOR LOCKED indicatorlightto turnoff. When thisindicatorlightturnsOFF the oven door may be opened.
3.RestartSelectClean ifneeded.
Importont notes:
*If Select Clean is active and a power failure occurs, the oven may not have thoroughly cleaned. This would depend on how much cleaning time had elapsed before the power failure. If needed after power is restored, set Select Clean again.
17