I_ | SECTION 4 _ |
OTHER THINGS TO KNOW
A. | DIMENSIONS | / SPECIFICATIONS |
|
| |
|
|
| Pretreatment | Needed | |
|
|
| For Higher | Amounts | |
|
| Supply Water | Limits | Listed | |
MAX, WATER HARDENSS: | 10 gpg | Water Softener | |||
|
|
| Water | Softener and/or | |
MAX, CLEAR WATER IRON: | 2 ppm |
| Iron Filter | ||
MAX, CHLORINE*: | 1 ppm | Activated Iron Filter | |||
MAX, TANNIN: | 3 ppm |
|
|
| |
MAX, pH: | 8,0 |
|
|
| |
MAX, NITRATES: | 2 mg/L |
|
|
| |
MAX, SUSPENDED SOLDS*: | 1,0 NTU |
|
| ||
INLET WATER PRESSURE LIMITS: | ....................... | psi |
|
| |
MAX, INLET WATER TEMPERATURE: | 120°F |
|
|
| |
MIN, INLET WATER FLOW: | 4 gat/min, |
|
| ||
MIN, INLET AND OUTLET PIPE SIZE: | 3/4 inch |
|
| ||
BACKWASH FLOW RATE (at 35 psi | inlet pressure): | 1 gal/min. |
|
| |
MIN, SALT USAGE AT EACH REGENERATION: | 5 Ibs |
|
|
| |
MIN, FREQUENCY OF REGENERATIONS: | every 2 days |
|
| ||
CAPACITY RATING: | See Rating Decal on Filter |
|
| ||
* continuous |
|
|
|
|
|
Problems, Questions? Call