Trane UH-SVX01A-EN manual Hot Water Performance Data, IV. Capacity AT Other Rates, Water Flow

Page 47

Hot Water Performance Data

Table 29. Model S Serpentine and Header Type (continued)

120

87,100

8.8

102

0.39

1/3

1140

1900

900

4.5

III

 

(25.5)

(.555)

(39)

(.119)

(.249)

 

(.897)

(4.572)

 

 

 

 

 

 

 

 

 

 

 

 

 

132

95,800

9.6

104

0.41

1/3

1140

2000

950

4.5

IV

 

(28.1)

(.606)

(40)

(.125)

(.249)

 

(.944)

(4.826)

 

 

 

 

 

 

 

 

 

 

 

 

 

144

104,000

10.4

104

0.43

1/3

1140

2200

1000

4.5

IV

 

(30.5)

(.656)

(40)

(.131)

(.249)

 

(1.038)

(5.080)

 

 

 

 

 

 

 

 

 

 

 

 

 

156

113,000

11.3

100

0.53

1/3

1140

2600

1150

4.5

IV

 

(33.1)

(.713)

(38)

(.162)

(.249)

 

(1.227)

(5.842)

 

 

 

 

 

 

 

 

 

 

 

 

 

180

118,000

11.8

110

0.6

1/3

1140

2200

800

4.5

III

 

(34.6)

(.744)

(43)

(.183)

(.249)

 

(1.038)

(4.064)

 

 

 

 

 

 

 

 

 

 

 

 

 

204

148,000

14.9

107

0.79

1/3

1140

2900

1000

4.5

IV

 

(43.4)

(.940)

(42)

(.241)

(.249)

 

(1.369)

(5.080)

 

 

 

 

 

 

 

 

 

 

 

 

 

240

174,000

17.4

106

1.06

1/3

1140

3500

900

4.5

IV

 

(51.0)

(1.098)

(41)

(.323)

(.249)

 

(1.652)

(4.572)

 

 

 

 

 

 

 

 

 

 

 

 

 

280

209,100

21.0

106

1.33

1/2

1100

4200

980

5.4

IV

 

(61.3)

(1.325)

(41)

(.405)

(.373)

 

(1.982)

(4.978)

 

 

 

 

 

 

 

 

 

 

 

 

 

300

230,000

23.0

102

2.1

1/2

1100

5000

700

5.4

IV

 

(67.4)

(1.451)

(39)

(.640)

(.373)

 

(2.360)

(3.556)

 

 

 

 

 

 

 

 

 

 

 

 

 

360

261,300

26.2

103

2.1

1/2

1100

5500

1000

5.4

IV

 

(76.6)

(1.653)

(39)

(.640)

(.373)

 

(2.596)

(5.080)

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance based on 200°F (93°C) EWT, 60°F (16°C) E.A.T., 20°F (11°C)TD.

For Fan Diameter see Pages 41 and 42.

* For the lower output, an optional Speed Controller must be ordered.

†Stated AMP is full load for standard motors. AMP draw varies by motor manufacturer ± 0.2 AMPS. Please see your unit's motor data plate for exact (FLA) Full Load Amp rating.

Table 30. Hot Water Calculations and Correction Factors S Type

EXAMPLE:

UNIT SIZE: __________________ 024

Entering Water Temp. _______ 160°F

Entering Air Temp. ___________ 40°F

Water Temperature Drop _______ 10°F

I. CAPACITY @ 20° TD: A. For 200° EWT, 60° EAT

Read output directly from Table 29, 17,400 BTU/HR (Ref., Std. 024)

B. For EWT and/or EAT above or below

Multiply output from Table 29 by factor from 17,400 x .878 = 15,277 BTU/HR.

Standard

Table 31

II.CAPACITY AT OTHER TD's Multiply output obtained in IA. Or IB. (above) IA-17,400 x 1.15 = 20,010 BTU/HR.

A. For TD's from 5 to 60°F

by appropriate factor from Table 32

-OR-

 

 

IB-15,277 x 1.15 = 17,569 BTU/HR.

 

 

 

III. GPM AT OTHER TD's

Multiply GPM of unit for 20° TD, from

1.8 x 2.30 = 4.14 GPM (Applies only to units

A. For TD's from 5 to 60°F

Table 29 by appropriate factor from Table 32

with Std. 200° EWT, 60° EAT.) For all others

 

 

calculate using formula-GPM = BTU/500 x TD

 

 

 

IV. CAPACITY AT OTHER RATES OF

Multiply output from Table 29 by factor from

 

WATER FLOW

Table 34.

 

 

 

 

V. PRESSURE LOSS AT OTHER TD's

Multiply P.D. of unit for 20°TD, from Table 29

.014 x 5.00 = .07 Ft. H2O

A. For TD's from 5 to 60°F

by appropriate factor from the Table 32

 

 

 

 

UH-SVX01A-EN

47

Image 47
Contents Unit Heaters Hazard Identification Preface and Warnings and CautionsContents Description Service Model Number DescriptionModel Number Description Digit 8-VOLTAGE Model Number Description300 360 LocationModel Maximum Mounting HT Approx. Max Throw ft mFour Point Suspension-Shelf Mounted Motors Only LocationForced HOT Water Forced HOT Water High Pressure Steam LOW Pressure Steam Gravity LOW Pressure Vapor or Vacuum Structural Integrity InstallationPeriodic Service Heavy Objects Lifting/Suspension Methods= Low Speed = Low output model with all air ports open InstallationUnit Size Steam Pressure PSI 17.5Spread ft m Maximum SpreadSteam Pressure PSI Unit Size Model NoFt m Diffuser Cone See a See B Standard Low Output ModelPressure Temperature SteamTemperature WaterPiping Installation Unit Mounting Heavy Objects Installation S TypeLouver Cone Diffuser Fan Guard/Louver InstallationVertical Unit with Osha Fan Guard Vertical Unit with Louver Cone DiffuserUnit Capacity MBH Fan Dia Min Dimensional DataDimensional Data P Model ModelsMBH Dimensional DataModels Roughing in Dimensional Data Model Size Unit Capacity FanDIAM. inches Ship WT. lbs Dimensional Data S ModelInches NO. NOM. FANHeader Type Models 18 thru NOM FAN Approx Diam Ship Header ModelsApproximate factors at varying altitudes Technical DataTechnical Data S Models Corrections When Using Glycol Solution in SystemCategory of Area Sound Rating Technical DataTechnical Data P Model Options S Models OptionsVertical Louver Cone Diffuser optional OptionsOptions P Models Operation Thermostat Wiring and LocationElectrical Connections Electrical Connections P Model Hazardous VoltageFan Motor Connections Low Voltage CCW Internal Marathon Electrical ConnectionsSpeed Controller with Manual Starting Switch Wiring Installation P ModelElectrical Connections S Model Hazardous Voltage Manual Control with Three Phase MotorWiring Installation S Model Electrical Connections AMP MCA MOP RPM Motor DataMotor Data P Models Voltage Selections Standard Totally Enclosed Motor Type MT=11145 Motor DataExplosion Proof with Thermal Overload Motor Type MT=2 Unit ModelExplosion Proof with Thermal Overload Motor Type Totally Enclosed Motor TypeBTU Steam Performance DataModel S Header Type Only OutputSteam Calculations and Correction Factors Steam Performance DataKg/hr Sq. m Properties of Saturated SteamModel P Standard Units Steam Pressure in Psig kPa037 Low Output Standard Vertical Units with All Air Ports Open13.8 34.5 68.9 103.4 137.9 206.8 275.8 344.7 517.1 Steam Calculations and Correction Factors P StyleSteam Correction Factors Based on 2 LBS. Steam 60 E.A.T Entering Steam Pressure LBS. PER SQ. IN. Saturated AIR TempCFM FPM Hot Water Performance DataModel S Serpentine and Header Type BTU/HRWater Flow Hot Water Performance DataHot Water Calculations and Correction Factors S Type IV. Capacity AT Other RatesTemperat Entering Entering Water Temperature F C AIRMinimum Water Flow Heating Capacity Factors for Various Rates of Water FlowCFM Type Standard Output Units117.6 24.24 108.8 34.5 529 318 42.7 138.0 041 720152.2 376 11,000 2250 237 1165 133 11.430 470.9 32.35Hot Water Performance Data IV. Pressure Loss AT Other TDs HOT Water Calculations and Correction Factor P StyleCapacity @ 20 TD II. Capacity AT Other TDs10 6 15 8 20 Minimum Water Flow GPMRotating Components MaintenancePeriodic Service Hazardous Voltage Cleaning the UnitAdditional P Model Instructions MaintenanceFan and Motor Assembly Troubleshooting GuideLimited Warranty P Model Warranty InfoLimited Warranty S Model Warranty Info Page Trane

UH-SVX01A-EN specifications

The Trane UH-SVX01A-EN is an advanced unit ventilator designed to provide efficient and reliable heating, cooling, and ventilation in various commercial and educational applications. This unit is particularly engineered for use in schools, offices, and healthcare facilities, ensuring optimal indoor air quality while maintaining energy efficiency.

One of the main features of the UH-SVX01A-EN is its innovative design that incorporates cutting-edge technologies for enhanced performance. The unit is equipped with a high-efficiency fan and motor system that operates quietly while delivering consistent airflow. This ensures a comfortable environment for occupants without the disruptive noise common in traditional ventilation systems.

Another standout characteristic of the UH-SVX01A-EN is its versatility. It offers multiple configuration options, allowing it to be tailored to meet specific building requirements and occupant needs. The unit can be integrated with various control systems, including advanced building management systems, which provide precise temperature control and enhance energy savings.

The use of variable air volume technology allows the UH-SVX01A-EN to adjust airflow rates based on real-time occupancy and environmental conditions. This intelligent airflow management not only improves comfort but also significantly reduces energy consumption, aligning with sustainable building practices.

Additionally, Trane has incorporated a range of filtration options within the unit, which contribute to improved indoor air quality by capturing dust, allergens, and other airborne particulates. This makes the UH-SVX01A-EN an ideal choice for settings where air purity is paramount, such as healthcare environments.

Maintenance of the UH-SVX01A-EN is also user-friendly, with easy access to key components for servicing and inspections. Trane's commitment to reliability and efficiency is manifested in the durable materials and construction of this unit, ensuring longevity and lower lifetime operational costs.

In summary, the Trane UH-SVX01A-EN combines advanced technology, versatile configurations, and a focus on energy efficiency and indoor air quality. This unit ventilator is designed to meet the demands of modern buildings while supporting environmental sustainability initiatives. With its robust features and flexible integration options, the UH-SVX01A-EN stands out as a reliable solution for any commercial heating, cooling, and ventilation needs.