Trane UH-SVX01A-EN Motor Data, Explosion Proof with Thermal Overload Motor Type MT=2, Unit Model

Page 39

Motor Data

Table 17. Explosion Proof with Thermal Overload Motor Type [MT=2]

Unit Model

 

 

 

 

 

No.

AMP

MCA

MOP

HP

RPM

 

 

 

 

115/1/60† Operating Voltage

 

 

 

 

 

 

 

 

 

42

3.8

4.8

8.6

1/6

1140

 

 

 

 

 

 

64

3.8

4.8

8.6

1/6

1140

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

102

3.8

4.8

8.6

1/6

1140

 

 

 

 

 

 

122

3.8

4.8

8.6

1/6

1140

 

146

 

 

 

 

 

 

 

 

 

 

 

166

 

 

 

 

 

 

 

 

 

 

 

202

4.4

5.5

9.9

1/4

1140

 

 

 

 

 

 

252

4.4

5.5

9.9

1/4

1140

 

 

 

 

 

 

280

7.8

9.8

17.6

1/2

1140

 

 

 

 

208-230/460/3/60 Operating Voltage

 

 

 

 

 

 

 

 

 

42

1.0-1.0/0.5

1.3-1.3/0.6

2.3-2.3/1.1

1/6

1140

 

 

 

 

 

 

64

1.0-1.0/0.5

1.3-1.3/0.6

2.3-2.3/1.1

1/6

1140

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

102

1.0-1.0/0.5

1.3-1.3/0.6

2.3-2.3/1.1

1/6

1140

 

 

 

 

 

 

122

1.0-1.0/0.5

1.3-1.3/0.6

2.3-2.3/1.1

1/6

1140

 

146

 

 

 

 

 

 

 

 

 

 

 

166

 

 

 

 

 

 

 

 

 

 

 

202

1.1-1.1/0.55

1.4-1.4/0.7

2.5-2.5/1.2

1/4

1140

 

 

 

 

 

 

252

1.1-1.1/0.55

1.4-1.4/0.7

2.5-2.5/1.2

1/4

1140

 

 

 

 

 

 

280

1.9/0.95***

2.4/1.2

4.3/2.1

1/2

1140

 

 

 

 

 

 

336

3.1-3.2/1.6

3.9-4.0/2.0

7.0-7.2/3.6

3/4

1145

 

 

 

 

 

 

384

 

 

 

 

 

 

 

 

 

 

 

500

5.0/2.5***

6.5/3.3

11.7/5.9

1-1/2

1150

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

720

10.0/5.0***

12.5/6.3

22.5/11.3

3

1150

 

 

 

 

 

 

For Table 17

*Optional variable speed switch is available.

**These motors have automatic thermal over- load protection or impedance protection.

***These motors are 230/460 volts only.

† Models 336 through 720 are not available for

either Totally Enclosed or Explosion Proof

 

with Overload 115/1/60 motor types.

Note: All motors are constant

 

Motor Data: S Models

speed and operate at top

speed as indicated in motor

￿CAUTION

data. Models 18 through 108,

including A08, A18, A25 and

Voltage Selections

A36 can be run at reduced

Select appropriate AMP, MCA, and

speed with addition of

optional variable speed

MOP for the multiple voltage motors.

switch. This switch is factory-

For example, the AMP, MCA, and

calibrated for low and high

MOP for Models 360 with a 460 volt

speed ratings, with

Totally Enclosed motor is 1.3, 1.6, and

intermediate speeds infinitely

2.9 respectively.

controllable. Models 120

Also refer to Maintenance section for

through 360 operate at

additional motor data.

constant speed as indicated

UH-SVX01A-EN

 

in motor data. All 1/4 H.P. motors are P.S.C.

Note: Motors under 1/3 H.P. are totally enclosed, frame mounted, 115/1/60 with thermal overload protection and permanently lubricated sleeve bearings with optional speed controller available. 1/3 H.P. (115/1/60) motors are open frame constant speed with thermal over-load protection and ball bearings. 1/3 H.P. (230V) and 1/2 H.P. (230V) motors are open frame constant speed with thermal overload protection and ball bearings.

Note: 1/3 and 1/2 H.P. motors are available as 230V single and 3 phase in open frame and explosion-proof housings, all available as options. 1/3 and 1/2 H.P. motors operate at single speed only.

Note: Stated AMP draw is Full Load Amp (FLA). AMP draw varies by motor manufacturer ± 0.2 AMPS. Verify FLA per unit motor data plate.

39

Image 39
Contents Unit Heaters Hazard Identification Preface and Warnings and CautionsContents Service Model Number Description Model Number DescriptionDescription Digit 8-VOLTAGE Model Number Description300 360 LocationModel Maximum Mounting HT Approx. Max Throw ft mFour Point Suspension-Shelf Mounted Motors Only LocationForced HOT Water Forced HOT Water High Pressure Steam LOW Pressure Steam Gravity LOW Pressure Vapor or Vacuum Structural Integrity InstallationPeriodic Service Heavy Objects Lifting/Suspension Methods= Low Speed = Low output model with all air ports open InstallationUnit Size Steam Pressure PSI 17.5Spread ft m Maximum SpreadSteam Pressure PSI Unit Size Model NoFt m Diffuser Cone See a See B Standard Low Output ModelPressure Temperature SteamTemperature WaterPiping Installation Unit Mounting Heavy Objects Installation S TypeLouver Cone Diffuser Fan Guard/Louver InstallationVertical Unit with Osha Fan Guard Vertical Unit with Louver Cone DiffuserUnit Capacity MBH Fan Dia Min Dimensional DataDimensional Data P Model ModelsMBH Dimensional DataModels Roughing in Dimensional Data Model Size Unit Capacity FanDIAM. inches Ship WT. lbs Dimensional Data S ModelInches NO. NOM. FANHeader Type Models 18 thru NOM FAN Approx Diam Ship Header ModelsApproximate factors at varying altitudes Technical DataTechnical Data S Models Corrections When Using Glycol Solution in SystemTechnical Data Technical Data P ModelCategory of Area Sound Rating Options S Models OptionsOptions Options P ModelsVertical Louver Cone Diffuser optional Operation Thermostat Wiring and LocationElectrical Connections Electrical Connections P Model Hazardous VoltageFan Motor Connections Low Voltage CCW Internal Marathon Electrical ConnectionsSpeed Controller with Manual Starting Switch Wiring Installation P ModelElectrical Connections S Model Hazardous Voltage Manual Control with Three Phase MotorWiring Installation S Model Electrical Connections AMP MCA MOP RPM Motor DataMotor Data P Models Voltage Selections Standard Totally Enclosed Motor Type MT=11145 Motor DataExplosion Proof with Thermal Overload Motor Type MT=2 Unit ModelExplosion Proof with Thermal Overload Motor Type Totally Enclosed Motor TypeBTU Steam Performance DataModel S Header Type Only OutputSteam Calculations and Correction Factors Steam Performance DataKg/hr Sq. m Properties of Saturated SteamModel P Standard Units Steam Pressure in Psig kPa037 Low Output Standard Vertical Units with All Air Ports Open13.8 34.5 68.9 103.4 137.9 206.8 275.8 344.7 517.1 Steam Calculations and Correction Factors P StyleSteam Correction Factors Based on 2 LBS. Steam 60 E.A.T Entering Steam Pressure LBS. PER SQ. IN. Saturated AIR TempCFM FPM Hot Water Performance DataModel S Serpentine and Header Type BTU/HRWater Flow Hot Water Performance DataHot Water Calculations and Correction Factors S Type IV. Capacity AT Other RatesTemperat Entering Entering Water Temperature F C AIRMinimum Water Flow Heating Capacity Factors for Various Rates of Water FlowCFM Type Standard Output Units117.6 24.24 108.8 34.5 529 318 42.7 138.0 041 720152.2 376 11,000 2250 237 1165 133 11.430 470.9 32.35Hot Water Performance Data IV. Pressure Loss AT Other TDs HOT Water Calculations and Correction Factor P StyleCapacity @ 20 TD II. Capacity AT Other TDs10 6 15 8 20 Minimum Water Flow GPMRotating Components MaintenancePeriodic Service Hazardous Voltage Cleaning the UnitAdditional P Model Instructions MaintenanceFan and Motor Assembly Troubleshooting GuideWarranty Info Limited Warranty S ModelLimited Warranty P Model Warranty Info Page Trane

UH-SVX01A-EN specifications

The Trane UH-SVX01A-EN is an advanced unit ventilator designed to provide efficient and reliable heating, cooling, and ventilation in various commercial and educational applications. This unit is particularly engineered for use in schools, offices, and healthcare facilities, ensuring optimal indoor air quality while maintaining energy efficiency.

One of the main features of the UH-SVX01A-EN is its innovative design that incorporates cutting-edge technologies for enhanced performance. The unit is equipped with a high-efficiency fan and motor system that operates quietly while delivering consistent airflow. This ensures a comfortable environment for occupants without the disruptive noise common in traditional ventilation systems.

Another standout characteristic of the UH-SVX01A-EN is its versatility. It offers multiple configuration options, allowing it to be tailored to meet specific building requirements and occupant needs. The unit can be integrated with various control systems, including advanced building management systems, which provide precise temperature control and enhance energy savings.

The use of variable air volume technology allows the UH-SVX01A-EN to adjust airflow rates based on real-time occupancy and environmental conditions. This intelligent airflow management not only improves comfort but also significantly reduces energy consumption, aligning with sustainable building practices.

Additionally, Trane has incorporated a range of filtration options within the unit, which contribute to improved indoor air quality by capturing dust, allergens, and other airborne particulates. This makes the UH-SVX01A-EN an ideal choice for settings where air purity is paramount, such as healthcare environments.

Maintenance of the UH-SVX01A-EN is also user-friendly, with easy access to key components for servicing and inspections. Trane's commitment to reliability and efficiency is manifested in the durable materials and construction of this unit, ensuring longevity and lower lifetime operational costs.

In summary, the Trane UH-SVX01A-EN combines advanced technology, versatile configurations, and a focus on energy efficiency and indoor air quality. This unit ventilator is designed to meet the demands of modern buildings while supporting environmental sustainability initiatives. With its robust features and flexible integration options, the UH-SVX01A-EN stands out as a reliable solution for any commercial heating, cooling, and ventilation needs.