If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some

cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting

 

 

chart. If a problem cannot be remedied, please consult with your authorized electrician and do not attempt any electrical repairs

TROUBLE

SUGGESTED REMEDY

yourself.

 

1. If fan does not start:

1. check main and branch circuit fuses or circuit breakers.

 

2. check wire connections as performed in step #15 or #16 of installation.

 

CAUTION: Make sure main power is turned off.

 

3. Make sure forward/reverse switch is firmly in up or down position.

 

Fan will not operate when switch is in the middle.

 

4. If the fan still will not start, contact a qualified electrician.

 

Do not attempt to troubleshoot internal electrical connections yourself.

2. If fan sounds noisy:

1. check to make sure all screws in motor housing are snug (not over tightened).

 

2. check to make sure the screws which attach the fan blade holder to the motor are tight.

 

3. Some fan motors are sensitive to signals from Solid State variable speed controls.

 

DO NOT USe a Solid State variable speed control.

 

4. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear

 

after this period.

3. If fan wobbles:

All blades are weighed and grouped by weight. Natural woods vary in density which could

 

cause the fan to wobble even though all blades are weight-matched. The following

 

procedures should eliminate most of the wobble. check for wobble after each step.

1.check that all blades are screwed firmly into blade holders.

2.check that all blade holders are tightened securely to motor.

3.Make sure that canopy and mounting bracket are tightened securely to ceiling joist.

4.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.

4.If light does not work: 1. check to see that the wire connections in the switch housing are connected.

2.check for faulty light bulbs.

3.If light kit will still not operate, contact a qualified electrician for assistance.

NOTICE

This ‘energy Policy Act 2005’ compliant fan includes a device that limits the total wattage of its light fixture to 190 watts.

By installing a combination of light bulbs that exceeds 190 watts or if an electrical surge causes the wattage to exceed 190 watts, the light fixture will either dim the lights to 190 watts or will automatically turn off.

To restore the light levels, make sure the total wattage of the light bulbs does not exceed 190 watts and follow the applicable directions below:

For fans with Pull Chains:

Pull the light fixture’s pull chain two times to reset the light fixture. If the power to your fan is controlled by a toggle wall switch, it may be necessary to turn the power off and back on at the wall switch.

For fans with Wall Controls:

Press the light button on the wall control “off” and “on”

once to reset the light fixture.

For fans with Remote Controls:

If you verify the wattage and the lights do not turn on, press the light button on the remote control twice to reset the light fixture.

NOTE: If the procedures above do not reset the lights,

turn off the main power source, located at the breaker panel or box,

and then turn it on again.

21

Image 21
Contents 15.4 net weightETL-ES-Harmony-WH11 Peso netoETL-ES-Harmony-WH11 wire Cutters safety tiPsETL-ES-Harmony-WH11 PliersPinzas COnsejOs de seGuridadescalera de mano Pinzas de corteFor normal ceilings features CaraCterístiCasMay require a longer downrod sold separatelyPreParinG fOr installatiOn antes de la instalaCión Suelte los tornillos de ajuste 1 en el acoplador Loosen the set screws 1 on the couplingMOuntinG OPtiOns OPCiOnes de MOntaje MOuntinG BraCKet installatiOn instalaCión COn sOPOrte de MOntajeChoose a MOuntinG OPtiOn elija una OPCión de MOntajeOPCión COn Varilla VertiCal Para CielOrrasO nOrMal nOrMal dOwnrOd OPtiOnPROCEED TO PAGE 11, STEP CONTINÚE CON LA PÁGINA 11, PASOeXtended dOwnrOd OPtiOn OPCión COn Varilla VertiCal MÁs larGa Repeat this step for remaining blade assembly Blade installatiOn instalaCión de las PaletasRepeat this step for remaining blade Repita este paso para el aspa restanteMOuntinG MOntaje wall COntrOl wirinG OPtiOn wirinG OPtiOns OPCión de CaBleadOPull CHain wirinG OPtiOn OPCión de CaBleadO Para Cadenilla de tirOseCure tO CeilinG aseGure el VentiladOr al CielOrrasO liGHt fiXture installatiOn instalaCión del artefaCtO luMinOsO 3. Push the connections neatly into the mounting ring Instale 2 bombillas tipo B incluido de 40 W Install 2 x 40W type B bulbs includedETL-ES-Harmony-WH11 OPeratiOn and MaintenanCe MaintenanceOperation FUNCIONAMIENTO CUIDADO Y MANTENIMIENTOOPeraCión y ManteniMientO For fans with Remote Controls trOuBlesHOOtinG GuideTROUBLE SUGGESTED REMEDYPROBLEMA Guía Para sOluCiOnar PrOBleMas3. NO USE un control de velocidad variable de estado sólido 2. compruebe si hay lámparas defectuosasETL-ES-Harmony-WH11 titular de la licencia de Westinghouse Electric Corporation