Swisher ZT18542 manual Battery Ground Connection AT Engine

Page 5

A neutral switch is located at the lower end of both drive control handles and is activated when the handles are outward in the neutral position. Check that the plunger buttons on both switches are depressed at least 3/8 inch. Loosening the two mounting screws and sliding the switch to the side can adjust these. Ohmmeter should go to zero when checking continuity across switch terminals with plungers depressed.

If any of the switches in this circuit tested bad, install a new one and perform Test #4 again. If all switches are good, a connecting wire must be at fault. Don’t move past Test #4 until it assures a good circuit. When you do get good results, hook all wires back to original position and try the ignition switch again. If no results, you will need to replace the ignition switch.

This panel is located right in front of the battery. It is accessible by removing the plate below the front edge of the seat.

With PTO switch in the off position, meter should go to zero when checking continuity across these two terminals.

BATTERY GROUND CONNECTION AT ENGINE

Negative battery ground on ZT18542

Negative battery ground on ZT2350

2

Image 5
Contents Repair Manual Page Table of Contents Always Check Fuse First If Engine WON’T CrankBattery Ground Connection AT Engine Engine Cranks but WON’T Start Engine Stalls When PTO is EngagedIf PTO Clutch will not Engage Hour Meter not Operating Wiring DiagramStarter Solenoid Wire Identification AT Switches Ignition SwitchPTO Switch Plug Wiring Harness Plug to Engine Wire Identification on ZT18542Wiring Harness to Engine Plug Connection Wire Identification on ZT2350 Used on ZT18542 Carburetor Fuel SolenoidUsed on ZT2350 Used on the ZT2350 Battery Charging SystemsAdjustment of Steering Adjusting the Drive ControlsTracking Adjustments Replacement of the Hydro Unit Repairing or Replacing Blade Driver Clutch drive belt replacement Belt Replacement RoutingQuick Reference Replacement PartsSwisher Mower & Machine CO. INC Corporate Drive Series