Every week or more often if necessary

The filter must be cleaned regularly in order to maintain the ion density.

Filter soiling depends on the usage environment, so clean the filter about once a week or whenever the filter is clogged, even if the Filter Clean Light has not turned on.

1 Gently remove dust from the filter of back side by using a vacuum cleaner.

<For Stubborn Dirt>

Remove and rinse in water. (Use a soft sponge if the dirt does not come off easily.)

Be careful the cushioning material does not come off.

Rinse

Wipe with a dry cloth. Reattach

Filter

(Dry in the shade.)

Do not press the vacuum cleaner strongly against the filter, or the filter could be damaged.

If using synthetic kitchen detergent, rinse well to remove all traces of the detergent. Also, be sure to dry the filter in the shade.

2 Press the Reset Button for at least 3 seconds.

Once cleaning is completed, connect the car adapter, then press and hold in the Reset Button for at least 3 seconds to turn off the filter clean light.

Filter Clean Light

Filter Clean Light will be lit after approx. 3 months (approx. 720 hours), when operated 8 hours a day.

Reset Button

Even if the Filter Clean Light is off, press and hold in the Reset Button for at least 3 seconds after cleaning.

RESET (Press 3sec.)

MODE

 

FILTER

RESET

 

CLEAN

(Press 3sec.)

Filter Clean

UNIT

 

 

 

Light

 

MODE

When the Reset Button is pressed and held in for at least 3 seconds, the light flashes twice then turns off.

E-8

Image 10
Contents IG-BC2J ENGLISHPage CONTENTS IMPORTANT SAFETY INSTRUCTIONS ...............E-2PLASMACLUSTER ION GENERATING UNIT REPLACEMENT.. E-10 TROUBLESHOOTINGPlease read instructions carefully before using this unit as below IMPORTANT SAFETY INSTRUCTIONSWARNINGS - To reduce the risk of electric shock, fire or injury CAUTIONS CONCERNING OPERATION Power Input Terminal Filter Cover Reset ButtonFilter Clean Light PARTS NAMEConnecting the car adapter and installing the unit INSTALLATION GUIDANCE1 Remove the filter cover Cautions on wiring the car adapter 4 Insert the cigar plug into the cigar lighter socketCautions on installation HIGH OPERATIONTo select the preferred mode Press2 Press the Reset Button for at least 3 seconds CLEANING AND MAINTENANCEFILTER Filter Clean LightMAIN UNIT Every month or more often if necessary Plasmacluster Ion Generating Unit electrode sectionAFTER THE UNIT MAINTENANCE If Plasmacluster ions are not releasedPLASMACLUSTER ION GENERATING UNIT REPLACEMENT Replacement of Plasmacluster Ion Generating UnitFor Disposal REPLACING THE FUSE SPECIFICATIONSHOW TO REPLACE 1 Turn the tip of the cigar plug and remove itProblem TROUBLESHOOTINGWHAT TO DO 1. In the European Union INFORMATION ON DISPOSALA. Information on Disposal for Users private households 2. In other Countries outside the EUWARRANTY WARRANTY PERIODSCongratulations on Your Purchase Consumer Electronic ProductsSHARP APPROVED SERVICE CENTRE SHARP CUSTOMER SERVICESAUSTRALIA 1300MEMO SHARP CORPORATION OF NEW ZEALAND LIMITED SHARP ELECTRONICS Europe GmbHA. B. N 4 Furzeground Way, Stockley Park, Uxbridge, Middlesex, UB11 1EZ