Sharp IG-BC2J Plasmacluster Ion Generating Unit electrode section, English, Fix it with a screw

Page 11
MAIN UNIT Every month or more often if necessary
Do not touch the Terminal connections

MAIN UNIT Every month or more often if necessary

Wipe with a dry soft cloth.

<For Stubborn Dirt> Use water and a mild detergent. And then, wipe with a wet cloth. Make sure to dry out the main unit.

Plasmacluster Ion Generating Unit (electrode section)

If Plasmacluster ions are not released

1 Remove the filter cover and a unit connection plug.

ENGLISH

2 Remove a screw fixing a unit with coin etc..

3 Remove the dust from the electrode

section of the unit with a cotton swab.

electrode section

Use caution when cleaning electrodes as their positions are fixed and any bending or changing of shape may cause irreparable damage to the Plasmacluster Ion Generating Unit.

4

5

Fix it with a screw.

Connect a unit connection plug and set the filter cover.

<AFTER THE UNIT MAINTENANCE>

Press the Operation Button and check the

Unit Replacing Lighting.

E-9

Image 11
Contents ENGLISH IG-BC2JPage TROUBLESHOOTING IMPORTANT SAFETY INSTRUCTIONS ...............E-2PLASMACLUSTER ION GENERATING UNIT REPLACEMENT.. E-10 CONTENTSWARNINGS - To reduce the risk of electric shock, fire or injury IMPORTANT SAFETY INSTRUCTIONSPlease read instructions carefully before using this unit as below CAUTIONS CONCERNING OPERATION PARTS NAME Reset ButtonFilter Clean Light Power Input Terminal Filter Cover1 Remove the filter cover INSTALLATION GUIDANCEConnecting the car adapter and installing the unit Cautions on installation 4 Insert the cigar plug into the cigar lighter socketCautions on wiring the car adapter Press OPERATIONTo select the preferred mode HIGHFilter Clean Light CLEANING AND MAINTENANCEFILTER 2 Press the Reset Button for at least 3 secondsIf Plasmacluster ions are not released Plasmacluster Ion Generating Unit electrode sectionAFTER THE UNIT MAINTENANCE MAIN UNIT Every month or more often if necessaryFor Disposal Replacement of Plasmacluster Ion Generating UnitPLASMACLUSTER ION GENERATING UNIT REPLACEMENT 1 Turn the tip of the cigar plug and remove it SPECIFICATIONSHOW TO REPLACE REPLACING THE FUSEWHAT TO DO TROUBLESHOOTINGProblem 2. In other Countries outside the EU INFORMATION ON DISPOSALA. Information on Disposal for Users private households 1. In the European UnionConsumer Electronic Products WARRANTY PERIODSCongratulations on Your Purchase WARRANTY1300 SHARP CUSTOMER SERVICESAUSTRALIA SHARP APPROVED SERVICE CENTREMEMO 4 Furzeground Way, Stockley Park, Uxbridge, Middlesex, UB11 1EZ SHARP ELECTRONICS Europe GmbHA. B. N SHARP CORPORATION OF NEW ZEALAND LIMITED